Measurement of endodontic file lengths: A density profile plot analysis

被引:6
作者
Piepenbring, ME
Potter, BJ
Weller, RN [1 ]
Loushine, RJ
机构
[1] Med Coll Georgia, Sch Dent, Dept Endodont, Augusta, GA 30912 USA
[2] Med Coll Georgia, Sch Dent, Dept Oral Diag & Patient Serv, Augusta, GA 30912 USA
关键词
D O I
10.1097/00004770-200010000-00009
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The purpose of this study was to evaluate measurements of endodontic files of known length and diameter using a density profile plot analysis of digital images. Ten single-rooted teeth with relatively straight roots in cadaver specimens were used. The crowns of the teeth were removed and a rectangular orthodontic wire, 5.13 mm in length, was placed horizontally on the occlusal surface to serve as a calibration reference point. The #8, #10, #15, and #20 FlexOFiles were measured to the nearest 0.5 mm and then placed to four working lengths that terminated within the apical third of each root. A GE X-ray unit and a Schick CDR #2 sensor were used to digitally acquire 160 images. The digital images were placed in random order and an independent, blinded investigator determined the file length using a density profile plot analysis. The measurements generated by the histogram analysis (experimental) were compared with the original clinical measurements. The paired t test, intraclass correlation coefficient, and the Bradley-Blackwood test were used to assess reliability. The results revealed that the means of the experimental measurements of all file sizes were within 0.5 mm of the known lengths and were always shorter than the known lengths. Also, the larger the file size the less deviation from the known lengths: #20, -0.16 mm (p = 0.0001); #15, -0.21 mm (p = 0.0001); #10, -0.34 mm (p = 0.0001); and #3, -0.45 mm (p = 0.0001). This study demonstrated that the density profile plot analysis might be a useful adjunct for the measurement of endodontic file lengths on a digital image.
引用
收藏
页码:615 / 618
页数:4
相关论文
共 16 条
[1]  
Borg E, 1996, ENDOD DENT TRAUMATOL, V12, P20
[2]   RADIOVISIOGRAPHY VERSUS CONVENTIONAL RADIOGRAPHY FOR DETECTION OF SMALL INSTRUMENTS IN ENDODONTIC LENGTH DETERMINATION .1. IN-VITRO EVALUATION [J].
ELLINGSEN, MA ;
HARRINGTON, GW ;
HOLLENDER, LG .
JOURNAL OF ENDODONTICS, 1995, 21 (06) :326-331
[3]   COMPARISON OF 3 IMAGING TECHNIQUES FOR ASSESSING ENDODONTIC WORKING LENGTH [J].
GRIFFITHS, BM ;
BROWN, JE ;
HYATT, AT ;
LINNEY, AD .
INTERNATIONAL ENDODONTIC JOURNAL, 1992, 25 (06) :279-287
[4]   RADIOGRAPHIC DETERMINATION OF CANAL LENGTH - DIRECT DIGITAL RADIOGRAPHY VERSUS CONVENTIONAL RADIOGRAPHY [J].
HEDRICK, RT ;
DOVE, SB ;
PETERS, DD ;
MCDAVID, WD .
JOURNAL OF ENDODONTICS, 1994, 20 (07) :320-326
[5]  
Lavelle CLB, 1995, ENDOD DENT TRAUMATOL, V11, P253
[6]   PRESENTATION AND PHYSICAL EVALUATION OF RADIO VISIOGRAPHY [J].
MOUYEN, F ;
BENZ, C ;
SONNABEND, E ;
LODTER, JP .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1989, 68 (02) :238-242
[7]   COMPARISON OF RADIOVISIOGRAPHY WITH RADIOGRAPHIC FILM IN ROOT LENGTH DETERMINATION [J].
ONG, EY ;
FORD, TRP .
INTERNATIONAL ENDODONTIC JOURNAL, 1995, 28 (01) :25-29
[8]   THE USE OF E-SPEED FILM FOR ROOT-CANAL LENGTH DETERMINATION [J].
POWELLCULLINGFORD, AW ;
FORD, TRP .
INTERNATIONAL ENDODONTIC JOURNAL, 1993, 26 (05) :268-272
[9]   AN IN-VITRO COMPARISON OF 10 RADIOGRAPHIC METHODS FOR WORKING LENGTH ESTIMATION [J].
RUSHTON, VE ;
SHEARER, AC ;
HORNER, K ;
CZAJKA, J .
INTERNATIONAL ENDODONTIC JOURNAL, 1995, 28 (03) :149-153
[10]   IMAGE QUALITY OF DIRECT DIGITAL INTRAORAL X-RAY SENSORS IN ASSESSING ROOT-CANAL LENGTH - THE RADIOVISIOGRAPHY, VISUALIX VIXA, SENS-A-RAY, AND FLASH DENT SYSTEMS COMPARED WITH EKTASPEED FILMS [J].
SANDERINK, GCH ;
HUISKENS, R ;
VANDERSTELT, PF ;
WELANDER, US ;
STHEEMAN, SE .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1994, 78 (01) :125-132