Determination of cadmium by FAAS after on-line enrichment using a mini column packed with Amberlite XAD-2 loaded with TAM

被引:66
作者
Melo, MHA
Ferreira, SLC
Santelli, RE
机构
[1] Univ Fed Bahia, Inst Quim, BR-40170290 Salvador, BA, Brazil
[2] Univ Fed Fluminense, Dept Geoquim, BR-24020 Rio De Janeiro, Brazil
关键词
D O I
10.1016/S0026-265X(00)00029-1
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A procedure for determination of trace amounts of cadmium with on-line preconcentration has been proposed. It is based on chemical sorption of cadmium(II) ions onto a minicolumn packed with Amberlite XAD-2 resin loaded with TAM reagent. After being preconcentrated, cadmium was eluted by 0.50 mol l(-1) hydrochloric acid solution and straight determined on-line by flame atomic absorption spectrometry. A time-based technique was used. Chemical and flow variables as well as concomitant ions were studied in the developed procedure. Detection limit (3 sigma, n = 22) was 1.2 mu g l(-1) for the analytical curve within the range of 0-200.0 mu g l(-1). An enrichment factor of 108 and a retention efficiency of 75.6% were achieved for a sample volume of 5.2 mi (1 min preconcentration time). The precision of the continuous Preconcentration method, calculated as the relative standard deviation in sample solutions containing 10 mu g l(-1) of cadmium was 4 and 9%, regarding repeatability and reproducibility, respectively. The selectivity of the proposed procedure was also evaluated. Results showed that iron(III), zinc(II), nickel(II), manganese(II), aluminum(III), copper(II), lead(II), cobalt(II), chromium(VI) (200 mu g l(-1) concentration) did not interfere during cadmium determination (10.0 mu g l(-1) concentration). Achieved analytical results for rice flour (NIES 10c) and lobster hepatopancreas (TORT-1) standard reference materials were in good agreement with the certified values. A high sample throughput (40 samples h(-1)), preconcentration factor and simplicity are the main advantages in this analytical procedure. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:59 / 65
页数:7
相关论文
共 20 条
[1]   Improved dithiocarbamate/oxine solvent extraction method for the preconcentration of trace metals from seawater using metal exchange back-extraction [J].
Batterham, GJ ;
Parry, DL .
MARINE CHEMISTRY, 1996, 55 (3-4) :381-388
[2]   CRITICAL COMPARISON OF METHODS FOR MERCURY DETERMINATION IN FISH [J].
BORTOLI, A ;
GEROTTO, M ;
MARCHIORI, M ;
MUNTAU, H ;
REHNERT, A .
MIKROCHIMICA ACTA, 1995, 119 (3-4) :305-310
[3]  
CHEN KL, 1992, HDB ORGANIC REAGENT
[4]   PRECONCENTRATION OF TRACE-METALS IN RIVER WATERS BY THE APPLICATION OF CHELATE ADSORPTION ON AMBERLITE XAD-4 [J].
ELCI, L ;
SOYLAK, M ;
DOGAN, M .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1992, 342 (1-2) :175-178
[5]   Determination of cadmium in mussels by flame atomic absorption spectrometry with preconcentration on a chelating resin in a flow injection system [J].
Enríquez-Domínguez, MF ;
Yebra-Biurrun, MC ;
Bermejo-Barrera, MP .
ANALYST, 1998, 123 (01) :105-108
[6]  
Fang Z., 1993, FLOW INJECTION SEPAR
[7]   Separation and preconcentration of cobalt after sorption onto amberlite XAD-2 loaded with 2-(2-thiazolylazo)-p-cresol [J].
Ferreira, SLC ;
de Brito, CF .
ANALYTICAL SCIENCES, 1999, 15 (02) :189-191
[8]   Nickel determination in saline matrices by ICP-AES after sorption on Amberlite XAD-2 loaded with PAN [J].
Ferreira, SLC ;
de Brito, CF ;
Dantas, AF ;
de Araújo, NML ;
Costa, ACS .
TALANTA, 1999, 48 (05) :1173-1177
[9]   An on-line continuous flow system for copper enrichment and determination by flame atomic absorption spectroscopy [J].
Ferreira, SLC ;
Lemos, VA ;
Moreira, BC ;
Costa, ACS ;
Santelli, RE .
ANALYTICA CHIMICA ACTA, 2000, 403 (1-2) :259-264
[10]   Collection of trace heavy metals on dithizone-impregnated admicelles for water analysis [J].
Hiraide, M ;
Shibata, W .
ANALYTICAL SCIENCES, 1998, 14 (06) :1085-1088