Detection of mass lesions with MR colonography: Preliminary report

被引:80
作者
Luboldt, W
Steiner, P
Bauerfeind, P
Pelkonen, P
Debatin, JF
机构
[1] Univ Zurich Hosp, Inst Diagnost Radiol, CH-8091 Zurich, Switzerland
[2] Univ Zurich Hosp, Gastroenterol Sect, CH-8091 Zurich, Switzerland
关键词
colon; MR; neoplasms; gadolinium;
D O I
10.1148/radiology.207.1.9530299
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To evaluate the performance of magnetic resonance (MR) colonography in the detection of colorectal mass lesions. MATERIALS AND METHODS: Twenty-three patients underwent MR colonography preceding colonscopy. The colon was filled with a gadolinium-water mixture (1:100) with MR imaging guidance, and the patient was imaged prone and supine with a breath-hold three-dimensional spoiled gradient-recalled sequence. In addition, two-dimensional spoiled gradient-recalled images were acquired before and after intravenous administration of gadopentetate dimeglumine. Images were interactively analyzed on the basis of multiplanar reconstruction by two radiologists. For regions that were not conclusively assessable with multiplanar reconstruction, virtual intraluminal endoscopic images of the colon were reconstructed. MR findings were correlated with colonoscopic results. RESULTS: Two patients were excluded from the analysis; Findings in eight of 11 patients were correctly assessed as normal and in six of 10 as mass-positive. In the four patients with false-negative findings, one had two 8-mm polyps and the other three had polyps smaller than 5 mm. All nine-mass lesions larger than 10 mm, as well as four of the 10 polyps ranging between 5 and 10 mm, were detected, but all polyps smaller than 5 mm were missed. In contrast to the polyps less than 5 mm, the four missed polyps (5-10 mm) could be identified retrospectively on virtual intraluminal endoscopic images. Contrast enhancement was documented in 13 polyps. CONCLUSION: Three-dimensional MR colonography provided virtual colonscopic viewing and helped detection of colonic polyps.
引用
收藏
页码:59 / 65
页数:7
相关论文
共 30 条
  • [1] A comparison of fecal occult-blood tests for colorectal-cancer screening
    Allison, JE
    Tekawa, IS
    Ransom, LJ
    Adrain, AL
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1996, 334 (03) : 155 - 159
  • [2] MRI of bowel obstruction using the HASTE sequence
    Beall, DP
    Regan, F
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1996, 20 (05) : 823 - 825
  • [3] EXTRAVASCULAR TOXICITY OF 2 MAGNETIC-RESONANCE CONTRAST AGENTS - PRELIMINARY EXPERIENCE IN THE RAT
    COHAN, RH
    LEDER, RA
    HERZBERG, AJ
    HEDLUND, LW
    WHEELER, CT
    BEAM, CA
    NADEL, SN
    DUNNICK, NR
    [J]. INVESTIGATIVE RADIOLOGY, 1991, 26 (03) : 224 - 226
  • [4] Human aorta: Preliminary results with virtual endoscopy based on three-dimensional MR imaging data sets
    Davis, CP
    Ladd, ME
    Romanowski, BJ
    Wildermuth, S
    Knoplioch, JF
    Debatin, JF
    [J]. RADIOLOGY, 1996, 199 (01) : 37 - 40
  • [5] COMPARISON OF SERUM CA-19-9 AND CEA LEVELS IN A POPULATION AT HIGH-RISK FOR COLORECTAL-CANCER
    GOLDBERG, EM
    SIMUNOVIC, LM
    DRAKE, SL
    MUELLER, WF
    VERRILL, HL
    [J]. HYBRIDOMA, 1989, 8 (05): : 569 - 575
  • [6] Colorectal polyp detection with CT colography: Two- versus three-dimensional techniques - Work in progress
    Hara, AK
    Johnson, CD
    Reed, JE
    Ehman, RL
    Ilstrup, DM
    [J]. RADIOLOGY, 1996, 200 (01) : 49 - 54
  • [7] Detection of colorectal polyps by computed tomographic colography: Feasibility of a novel technique
    Hara, AK
    Johnson, CD
    Reed, JE
    Ahlquist, DA
    Nelson, H
    Ehman, RL
    McCollough, CH
    Ilstrup, DM
    [J]. GASTROENTEROLOGY, 1996, 110 (01) : 284 - 290
  • [8] TRENDS IN USE OF BARIUM ENEMA EXAMINATION, COLONOSCOPY, AND SIGMOIDOSCOPY - IS USE COMMENSURATE WITH RISK OF DISEASE
    KARASICK, S
    EHRLICH, SM
    LEVIN, DC
    HARFORD, RJ
    ROSETTI, EE
    RICCI, JA
    BEAM, LM
    GIGLIOTTI, JV
    [J]. RADIOLOGY, 1995, 195 (03) : 777 - 784
  • [9] Time-resolved contrast-enhanced 3D MR angiography
    Korosec, FR
    Frayne, R
    Grist, TM
    Mistretta, CA
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (03) : 345 - 351
  • [10] LEE PY, 1994, AM SURGEON, V60, P607