Aspects of column fabrication for packed capillary electrochromatography

被引:19
作者
Angus, PDA
Demarest, CW
Catalano, T
Stobaugh, JF
机构
[1] Univ Kansas, Dept Pharmaceut Chem, Lawrence, KS 66047 USA
[2] GD Searle & Co, Analyt R&D, Skokie, IL 60047 USA
关键词
column fabrication; electrochromatography; stationary phases; CEC;
D O I
10.1016/S0021-9673(00)00529-X
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Various parameters have been evaluated to develop a process for optimization of column manufacture for packed capillary electrochromatography (CEC). Spherisorb ODS-1 was packed into 75 mu m I.D. capillaries to establish a standard set of packing conditions to afford high-performance columns free of voids. Numerous silica-based packing materials including porous and non-porous reversed-phase and ion-exchange phases were employed to evaluate the applicability of the standard conditions. Success of column manufacture and performance demonstrate a relationship to the colligative properties of the packing materials under the applied conditions. Frequently encountered difficulties arising from inadequate column conditioning and void formation in the packed bed are identified and discussed. (C) 2000 Elsevier Science BN. All rights reserved.
引用
收藏
页码:347 / 365
页数:19
相关论文
共 70 条
[1]   PREPARATION AND EVALUATION OF SLURRY-PACKED CAPILLARY COLUMNS FOR NORMAL-PHASE LIQUID-CHROMATOGRAPHY [J].
ANDREOLINI, F ;
BORRA, C ;
NOVOTNY, M .
ANALYTICAL CHEMISTRY, 1987, 59 (19) :2428-2432
[2]   Method development in pharmaceutical analysis employing capillary electrochromatography [J].
Angus, PDA ;
Victorino, E ;
Payne, KM ;
Demarest, CW ;
Catalano, T ;
Stobaugh, JF .
ELECTROPHORESIS, 1998, 19 (12) :2073-2082
[3]  
Angus PDA, 1999, ELECTROPHORESIS, V20, P2349, DOI 10.1002/(SICI)1522-2683(19990801)20:12<2349::AID-ELPS2349>3.0.CO
[4]  
2-A
[5]   Sintered octadecylsilica as monolithic column packing in capillary electrochromatography and micro high-performance liquid chromatography [J].
Asiaie, R ;
Huang, X ;
Farnan, D ;
Horváth, C .
JOURNAL OF CHROMATOGRAPHY A, 1998, 806 (02) :251-263
[6]   MODIFIED METHOD FOR FILLING MICRO-HPLC-COLUMNS [J].
BACHMANN, K ;
HAAG, I ;
PROKOP, T .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1993, 345 (07) :545-546
[7]   EVALUATION OF THE PARAMETERS DETERMINING THE PERFORMANCE OF ELECTROCHROMATOGRAPHY IN PACKED CAPILLARY COLUMNS [J].
BEHNKE, B ;
GROM, E ;
BAYER, E .
JOURNAL OF CHROMATOGRAPHY A, 1995, 716 (1-2) :207-213
[8]   CAPILLARY ELECTROCHROMATOGRAPHY - SOME IMPORTANT CONSIDERATIONS IN THE PREPARATION OF PACKED CAPILLARIES AND THE CHOICE OF MOBILE-PHASE BUFFERS [J].
BOUGHTFLOWER, RJ ;
UNDERWOOD, T ;
PATERSON, CJ .
CHROMATOGRAPHIA, 1995, 40 (5-6) :329-335
[9]  
CARLSSON P, 1996, 18 INT S CAP CHROM R, V1, P1941
[10]  
Carney RA, 1999, HRC-J HIGH RES CHROM, V22, P29