A new design for a compact centrifugal blood pump with a magnetically levitated rotor

被引:33
作者
Asama, J
Shinshi, T
Hoshi, H
Takatani, S
Shimokohbe, A
机构
[1] Tokyo Inst Technol, Precis & Intelligence Lab, Midori Ku, Yokohama, Kanagawa 2268503, Japan
[2] Tokyo Inst Technol, Interdisciplinaty Grad Sch Sci & Engn, Yokohama, Kanagawa 2268503, Japan
[3] Tokyo Med & Dent Univ, Inst Biomat & Bioengn, Tokyo, Japan
关键词
D O I
10.1097/01.MAT.0000144364.62671.5A
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A compact centrifugal blood pump has been developed using a radial magnetic bearing with a two-degree of freedom active control. The proposed magnetic bearing exhibits high stiffness, even in passively controlled directions, and low power consumption because a permanent magnet, incorporated with the rotor, suspends its weight. The rotor is driven by a Lorentz force type of built-in motor, avoiding mechanical friction and material wear. The built-in motor is designed to generate only rotational torque, without radial and axial attractive forces on the rotor, leading to low power consumption by the magnetic bearing. The fabricated centrifugal pump measured 65 mm in diameter and 45 mm in height and weighed 0.36 kg. In the closed loop circuit filled with water, the pump provided a flow rate of 4.5 L/min at 2,400 rpm against a pressure head of 100 mm Hg. Total power consumption at that point was 18 W, including 2 W required for magnetic levitation, with a total efficiency of 5.7%. The experimental results showed that the design of the compact magnetic bearing was feasible and effective for use in a centrifugal blood pump.
引用
收藏
页码:550 / 556
页数:7
相关论文
共 14 条
[1]   RECENT STUDIES OF THE CENTRIFUGAL BLOOD PUMP WITH A MAGNETICALLY SUSPENDED IMPELLER [J].
AKAMATSU, T ;
TSUKIYA, T ;
NISHIMURA, K ;
PARK, CH ;
NAKAZEKI, T .
ARTIFICIAL ORGANS, 1995, 19 (07) :631-634
[2]   Prototype continuous flow ventricular assist device supported on magnetic bearings [J].
Allaire, PE ;
Kim, HC ;
Maslen, EH ;
Olsen, DB ;
Bearnson, GB .
ARTIFICIAL ORGANS, 1996, 20 (06) :582-590
[3]  
ASAMA J, 2003, P 7 INT S MAGN SUSP, P117
[4]   HeartMate III: Pump design for a centrifugal LVAD with a magnetically levitated rotor [J].
Bourque, K ;
Gernes, DB ;
Loree, HM ;
Richardson, JS ;
Poirier, VL ;
Barletta, N ;
Fleischli, A ;
Foiera, G ;
Gempp, TM ;
Schoeb, R ;
Litwak, KN ;
Akimoto, T ;
Watach, MJ ;
Litwak, P .
ASAIO JOURNAL, 2001, 47 (04) :401-405
[5]   DESIGN OF PERMANENT MULTIPOLE MAGNETS WITH ORIENTED RARE-EARTH COBALT MATERIAL [J].
HALBACH, K .
NUCLEAR INSTRUMENTS & METHODS, 1980, 169 (01) :1-10
[6]   A magnetically suspended and hydrostatically stabilized centrifugal blood pump [J].
Hart, RM ;
Filipenco, VG ;
Kung, RTV .
ARTIFICIAL ORGANS, 1996, 20 (06) :591-596
[7]   Washout hole flow measurement for the development of a centrifugal blood pump [J].
Nishida, M ;
Yamane, T ;
Asztalos, B .
ARTIFICIAL ORGANS, 1998, 22 (05) :386-392
[8]   Development status of terumo implantable left ventricular assist system [J].
Nojiri, C ;
Kijima, T ;
Maekawa, J ;
Horiuchi, K ;
Kido, T ;
Sugiyama, T ;
Mori, T ;
Sugiura, N ;
Asada, T ;
Umemura, W ;
Ozaki, T ;
Suzuki, M ;
Akamatsu, T ;
Westaby, S ;
Katsumata, T ;
Saito, S .
ARTIFICIAL ORGANS, 2001, 25 (05) :411-413
[9]  
ONUMA H, 2002, P 8 INT S MAGN BEAR, P3
[10]   A novel compact PMSM with magnetic bearing for artificial heart application [J].
Shen, JX ;
Tseng, KJ ;
Vilathgamuwa, DM ;
Chan, WK .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2000, 36 (04) :1061-1068