Lens opacities after nonmechanical versus mechanical corneal trephination for keratoplasty in keratoconus

被引:15
作者
Behrens, A [1 ]
Seitz, B [1 ]
Langenbucher, A [1 ]
Kus, MM [1 ]
Küchle, M [1 ]
Naumann, GOH [1 ]
机构
[1] Univ Erlangen Nurnberg, Eye Clin, Dept Ophthalmol, D-91054 Erlangen, Germany
关键词
D O I
10.1016/S0886-3350(00)00717-3
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To compare the lens opacity formation after penetrating keratoplasty (PKP) using nonmechanical excimer laser corneal trephination and mechanical motor trephination. Setting: University Eye Clinic, University of Erlangen-Nurnberg, Erlangen, Germany. Methods: Ninety-six patients with keratoconus (96 eyes) and clear crystalline lenses were randomly assigned to the nonmechanical trephination (NMT) group (n = 46; 35 men; mean age 38.2 years +/- 10.8 [SD]) or the mechanical trephination (MT) group (n = 50; 35 men; mean age 34.4 +/- 9.0 years). Suturing and postoperative treatment were identical. Dilated pupil biomicroscopy and slitlamp lens photography were performed preoperatively and postoperatively at 3 month intervals. Opacities were identified as cortical, nuclear, and posterior subcapsular and graded from 1 (mild) to 3 (severe). Results: Mean follow-up in the NMT/MT group was 3.2 +/- 1.3 years/3.4 +/- 1.1 years. Overall, incident opacities appeared in 23.9%/32.0% of eyes (4.3%/6.0% cortical; 19.6%/26.0% posterior subcapsular; 0%/0% nuclear) (P =.833). All cortical opacities in both groups were grade 1; posterior subcapsular opacities were grade 1 in 66.6%/61.5% of eyes and grade 2 in 22.2%/30.8% of eyes. One patient in each group presented grade 3 posterior subcapsular opacities. No differences between trephination methods were seen in a 5 year Kaplan-Meier cumulative risk of lens opacity formation (P =.763 cortical, P =.530 posterior subcapsular). Conclusion: In addition to its optical advantages, nonmechanical corneal trephination appears to have no adverse impact on cataract formation after PKP for keratoconus. J Cataract Refract Surg 2000; 26: 1605-1611 (C) 2000 ASCRS and ESCRS.
引用
收藏
页码:1605 / 1611
页数:7
相关论文
共 44 条
[11]  
KoralewskaMakar A, 1996, ACTA OPHTHALMOL SCAN, V74, P187
[12]  
KRUMEICH J, 1988, CLAO Journal, V14, P213
[13]   Nonmechanical excimer laser penetrating keratoplasty for perforated or predescemetal corneal ulcers [J].
Küchle, M ;
Seitz, B ;
Langenbucher, A ;
Naumann, GOH .
OPHTHALMOLOGY, 1999, 106 (11) :2203-2209
[14]   Blood-aqueous barrier after mechanical or nonmechanical excimer laser trephination in penetrating keratoplasty [J].
Kuchle, M ;
Nguyen, NX ;
Seitz, B ;
Langenbucher, A ;
Naumann, GOH .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1998, 125 (02) :177-181
[15]   Free-running erbium:YAG laser for nonmechanical trephination in penetrating keratoplasty:: first results of experimental trephination of human donor corneas [J].
Küchle, M ;
Behrens, A ;
Seitz, B ;
Langenbucher, A ;
Naumann, GOH .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 1999, 237 (10) :875-877
[16]   A NEW ELLIPTIC EXCISION FOR CORNEAL TRANSPLANTATION USING AN EXCIMER LASER [J].
LANG, GK ;
NAUMANN, GOH ;
KOCH, JW .
ARCHIVES OF OPHTHALMOLOGY, 1990, 108 (07) :914-915
[17]  
LANG GK, 1989, OPHTHALMIC SURG LAS, V20, P262
[18]  
LANG GK, 1989, OPHTHALMIC SURG, V86, P437
[19]  
Langenbucher A, 1999, INVEST OPHTH VIS SCI, V40, P582
[20]  
Langenbucher A, 1998, OPHTHALMIC SURG LAS, V29, P106