Assessing transient response of DFIG based wind turbines during voltage dips regarding main flux saturation and rotor deep-bar effect

被引:57
作者
Song, Zhanfeng [1 ]
Xia, Changliang [1 ]
Shi, Tingna [1 ]
机构
[1] Tianjin Univ, Dept Elect Engn, Tianjin 300072, Peoples R China
基金
中国国家自然科学基金;
关键词
Deep-bar effect; Doubly-fed-induction-generator (DFIG); Saturation; Transient response; Voltage dip; Wind energy; FED INDUCTION GENERATOR; SYSTEMS;
D O I
10.1016/j.apenergy.2010.04.009
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
With increasing wind power penetration, transient responses of doubly-fed-induction-generator (DFIG) based wind turbines gain attentive focus. Accurate prediction of transient performance of DAG under grid faults is required with increasing wind power penetration. Taking into account the main flux saturation and deep-bar effect, this paper concentrates on transient responses and stability of the DFIG system under symmetrical grid faults. Their roles played in the enhancement of system transient stability are clarified. The analyses proposed contribute greatly to proper selection, design and coordination of protection devices and control strategies as well as stability studies. (C) 2010 Elsevier Ltd. All rights reserved.
引用
收藏
页码:3283 / 3293
页数:11
相关论文
共 31 条
  • [1] Evaluating the impact of electrical grid connection on the wind turbine performance for Hofa wind farm scheme in Jordan
    Abderrazzaq, M. H.
    Aloquili, O.
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2008, 49 (11) : 3376 - 3380
  • [2] Controller for a small induction-generator based wind-turbine
    Ahshan, R.
    Iqbal, M. T.
    Mann, K. I.
    [J]. APPLIED ENERGY, 2008, 85 (04) : 218 - 227
  • [3] A new method to estimate Weibull parameters for wind energy applications
    Akdag, Seyit A.
    Dinler, Ali
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2009, 50 (07) : 1761 - 1766
  • [4] [Anonymous], NORD WORKSH POW IND
  • [5] Nonlinear control with wind estimation of a DFIG variable speed wind turbine for power capture optimization
    Boukhezzar, B.
    Siguerdidjane, H.
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2009, 50 (04) : 885 - 892
  • [6] A comparative study between three sensorless control strategies for PMSG in wind energy conversion system
    Brahmi, Jemaa
    Krichen, Lotfi
    Ouali, Abderrazak
    [J]. APPLIED ENERGY, 2009, 86 (09) : 1565 - 1573
  • [7] Fajardo L. A. R, 2007, PROC EUR C POWER ELE, P1
  • [8] Equivalent models of wind farms by using aggregated wind turbines and equivalent winds
    Fernandez, L. M.
    Garcia, C. A.
    Saenz, J. R.
    Jurado, F.
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2009, 50 (03) : 691 - 704
  • [9] A fault tolerant doubly fed induction generator wind turbine using a parallel grid side rectifier and series grid side converter
    Flannery, Patrick S.
    Venkataramanan, Giri
    [J]. IEEE TRANSACTIONS ON POWER ELECTRONICS, 2008, 23 (03) : 1126 - 1135
  • [10] Voltage dip generator for wind energy systems up to 5 MW
    Garcia-Gracia, Miguel
    Comech, M. Paz
    Sallan, Jesus
    Lopez-Andia, Diego
    Alonso, Oscar
    [J]. APPLIED ENERGY, 2009, 86 (04) : 565 - 574