Radio frequency coil technology for small-animal MRI

被引:158
作者
Doty, F. David [1 ]
Entzminger, George [1 ]
Kulkarni, Jatin [1 ]
Pamarthy, Kranti [1 ]
Staab, John P. [1 ]
机构
[1] Doty Sci Inc, Columbia, SC 29229 USA
关键词
small-animal MRI; surface coils; circular polarization volume coils; phased arrays; low-noise preamplifiers; decoupling;
D O I
10.1002/nbm.1149
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A review of the theory, technology, and use of radio frequency (RF) coils for small-animal MRI is presented. It includes a brief overview of MR signal-to-noise (S/N) analysis and discussions of the various coils commonly used in small-animal MR: surface coils, linear volume coils, birdcages, and their derivatives. The scope is limited to mid-range coils, i.e. coils where the product (fd) of the frequency f and the coil diameter d is in the range 2-30 MHz-m. Common applications include mouse brain and body coils from 125 to 750 MHz, rat body coils up to 500 MHz, and small surface coils at all fields. In this regime, all the sources of loss (coil, capacitor, sample, shield, and transmission lines) are important. All such losses may be accurately captured in some modern full-wave 3D electromagnetics software, and new simulation results are presented for a selection of surface coils using Microwave Studio 2006 by Computer Simulation Technology, showing the dramatic importance of the 'lift-off effect'. Standard linear circuit simulators have been shown to be useful in optimization of complex coil tuning and matching circuits. There appears to be considerable potential for trading S/N for speed using phased arrays, especially for a larger field of view. Circuit simulators are shown to be useful for optimal mismatching of ultra-low-noise preamps based on the enhancement-mode pseudomorphic high-electron-mobility transistor for optimal coil decoupling in phased arrays. Cryogenically cooled RF coils are shown to offer considerable opportunity for future gains in S/N in smaller samples. Copyright (C) 2007 John Wiley & Sons, Ltd.
引用
收藏
页码:304 / 325
页数:22
相关论文
共 97 条
[21]   Practical aspects of birdcage coils [J].
Doty, FD ;
Entzminger, G ;
Hauck, CD ;
Staab, JP .
JOURNAL OF MAGNETIC RESONANCE, 1999, 138 (01) :144-154
[22]  
Doty FD, 1999, J MAGN RESON, V140, P17, DOI 10.1006/jmre/1999.1828
[23]  
DOTY FD, 2000, Patent No. 6060882
[24]  
DOTY FD, 2003, 11 ISMRM TOR
[25]  
DOTY FD, 2003, 44 ENC SAV APR
[26]  
DOTY FD, 2002, 10 ISMRM HON
[27]  
DOTY FD, 2002, ENC AS
[28]  
DOTY FD, 1987, Patent No. 4641098
[29]  
DOTY FD, 2005, ROCK MOUNT C DENV
[30]  
DOTY FD, 2001, Patent No. 6175237