Femoral anatomical frame: assessment of various definitions

被引:31
作者
Della Croce, U
Camomilla, V
Leardini, A
Cappozzo, A
机构
[1] Ist Univ Sci Motorie, I-00198 Rome, Italy
[2] Ist Ortoped Rizzoli, Lab Anal Movimento, Bologna, Italy
[3] Univ Sassari, Dipartimento Sci Biomed, I-07100 Sassari, Italy
关键词
movement analysis; stereophotogrammetry; anatomical landmarks; anatomical frames; precision; joint kinematics;
D O I
10.1016/S1350-4533(03)00032-8
中图分类号
R318 [生物医学工程];
学科分类号
0831 [生物医学工程];
摘要
The reliability of the estimate of joint kinematic variables and the relevant functional interpretation are affected by the uncertainty with which bony anatomical landmarks and underlying bony segment anatomical frames are determined. When a stereo-photogrammetric system is used for in vivo studies, minimising and compensating for this uncertainty is crucial. This paper deals with the propagation of the errors associated with the location of both internal and palpable femoral anatomical landmarks to the estimation of the orientation of the femoral anatomical frame and to the knee joint angles during movement. Given eight anatomical landmarks, and the precision with which they can be identified experimentally, 12 different rules were defined for the construction of the anatomical frame and submitted to comparative assessment. Results showed that using more than three landmarks allows for more repeatable anatomical frame orientation and knee joint kinematics estimation. Novel rules are proposed that use optimization algorithms. On the average, the femoral frame orientation dispersion had a standard deviation of 2, 2.5 and 1.5degrees for the frontal, transverse, and sagittal plane, respectively. However, a proper choice of the relevant construction rule allowed for a reduction of these inaccuracies in selected planes to 1degrees rms. The dispersion of the knee adduction-abduction and internal-external rotation angles could also be limited to 1degrees rms irrespective of the flexion angle value. (C) 2003 IPEM. Published by Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:425 / 431
页数:7
相关论文
共 22 条
[1]
Correcting for deformation in skin-based marker systems [J].
Alexander, EJ ;
Andriacchi, TP .
JOURNAL OF BIOMECHANICS, 2001, 34 (03) :355-361
[2]
A COMPARISON OF THE ACCURACY OF SEVERAL HIP CENTER LOCATION PREDICTION METHODS [J].
BELL, AL ;
PEDERSEN, DR ;
BRAND, RA .
JOURNAL OF BIOMECHANICS, 1990, 23 (06) :617-621
[3]
Multiple anatomical landmark calibration for optimal bone pose estimation [J].
Cappello, A ;
Cappozzo, A ;
LaPalombara, PF ;
Lucchetti, L ;
Leardini, A .
HUMAN MOVEMENT SCIENCE, 1997, 16 (2-3) :259-274
[4]
GAIT ANALYSIS METHODOLOGY [J].
CAPPOZZO, A .
HUMAN MOVEMENT SCIENCE, 1984, 3 (1-2) :27-50
[5]
Surface-marker cluster design criteria for 3-D bone movement reconstruction [J].
Cappozzo, A ;
Cappello, A ;
DellaCroce, U ;
Pensalfini, F .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1997, 44 (12) :1165-1174
[6]
POSITION AND ORIENTATION IN-SPACE OF BONES DURING MOVEMENT - ANATOMICAL FRAME DEFINITION AND DETERMINATION [J].
CAPPOZZO, A ;
CATANI, F ;
DELLA CROCE, U ;
LEARDINI, A .
CLINICAL BIOMECHANICS, 1995, 10 (04) :171-178
[7]
A PROCEDURE FOR DETERMINING RIGID-BODY TRANSFORMATION PARAMETERS [J].
CHALLIS, JH .
JOURNAL OF BIOMECHANICS, 1995, 28 (06) :733-737
[8]
A SOLIDIFICATION PROCEDURE TO FACILITATE KINEMATIC ANALYSES BASED ON VIDEO SYSTEM DATA [J].
CHEZE, L ;
FREGLY, BJ ;
DIMNET, J .
JOURNAL OF BIOMECHANICS, 1995, 28 (07) :879-884
[9]
A GAIT ANALYSIS DATA-COLLECTION AND REDUCTION TECHNIQUE [J].
DAVIS, RB ;
OUNPUU, S ;
TYBURSKI, D ;
GAGE, JR .
HUMAN MOVEMENT SCIENCE, 1991, 10 (05) :575-587
[10]
Pelvis and lower limb anatomical landmark calibration precision and its propagation to bone geometry and joint angles [J].
Della Croce, U ;
Cappozzo, A ;
Kerrigan, DC .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1999, 37 (02) :155-161