Occlusion cuff position is an important determinant of the time course and magnitude of human brachial artery flow-mediated dilation

被引:91
作者
Berry, KL
Skyrme-Jones, RAP
Meredith, IT
机构
[1] Monash Univ, Monash Med Ctr, Ctr Cardiovasc, Clayton, Vic 3168, Australia
[2] Monash Univ, Monash Med Ctr, Ctr Heart & Chest Res, Clayton, Vic 3168, Australia
关键词
arteries; blood flow; endothelial function; ultrasound; flow-mediated vasodilation;
D O I
10.1042/CS20000028
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Non-invasive ultrasound techniques to assess flow-mediated vasodilation (FMD) are frequently used to assess arterial endothelial vasodilator function. However, the range of normal values varies considerably, possibly due to differences in methodological factors. We sought to determine the effect of occlusion cuff position on the time course and magnitude of brachial artery blood flow and flow-mediated dilation. Twelve healthy subjects underwent measurements of forearm blood flow using venous occlusion plethysmography (VOP) before and after 5 min of susprasystolic cuff inflation, using two randomly assigned occlusion cuff positions (upper arm and forearm). An additional 16 subjects underwent two brachial ultrasound studies, using the two cuff positions, to assess the extent and time course of changes in brachial artery diameter and blood flow. Maximum increase in blood flow (peak reactive hyperaemia), measured by VOP, occurred immediately upon each cuff deflation, but was greater after upper arm compared with forearm arterial occlusion (33.1 +/- 3.1 versus 22.8 +/- 2.2 ml/min per forearm tissue, P = 0.001). Maximal brachial artery FMD was significantly greater following upper arm occlusion (9.0 +/- 1.2%, mean +/- S.E.M.) compared with forearm occlusion (5.9 +/- 0.7%, P = 0.01). The time course of the change in brachial artery diameter was affected differently in response to each protocol. The time to peak dilation following upper arm occlusion was delayed by 22 s com pared with forearm occlusion. Occlusion cuff position is thus a powerful determinant of peak reactive hyperaemia, volume repaid and the extent and time course of brachial artery FMD. Positioning the cuff on the upper arm produces a greater FMD. These results highlight the need for comparisons between FMD studies to be made with care.
引用
收藏
页码:261 / 267
页数:7
相关论文
共 30 条
  • [21] Long-term estrogen therapy improves vascular function in male to female transsexuals
    New, G
    Timmins, KL
    Duffy, SJ
    Tran, BT
    OBrien, RC
    Harper, RW
    Meredith, IT
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1997, 29 (07) : 1437 - 1444
  • [22] Non-invasive detection of endothelial dysfunction
    Ramsey, M
    Goodfellow, J
    Bellamy, M
    Lewis, M
    Henderson, A
    [J]. LANCET, 1996, 348 (9020) : 128 - 129
  • [23] ENDOTHELIAL CONTROL OF ARTERIAL DISTENSIBILITY IS IMPAIRED IN CHRONIC HEART-FAILURE
    RAMSEY, MW
    GOODFELLOW, J
    JONES, CJH
    LUDDINGTON, LA
    LEWIS, MJ
    HENDERSON, AH
    [J]. CIRCULATION, 1995, 92 (11) : 3212 - 3219
  • [24] FLOW-INDUCED RELEASE OF ENDOTHELIUM-DERIVED RELAXING FACTOR
    RUBANYI, GM
    ROMERO, JC
    VANHOUTTE, PM
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY, 1986, 250 (06): : 1145 - 1149
  • [25] CHARACTERISTICS OF FLOW-MEDIATED BRACHIAL-ARTERY VASODILATION IN HUMAN-SUBJECTS
    SINOWAY, LI
    HENDRICKSON, C
    DAVIDSON, WR
    PROPHET, S
    ZELIS, R
    [J]. CIRCULATION RESEARCH, 1989, 64 (01) : 32 - 42
  • [26] Tawakol A, 1997, CIRCULATION, V95, P1119
  • [27] Uehata A, 1997, Vasc Med, V2, P87
  • [28] Changes in flow-mediated brachial artery vasoactivity with lowering of desirable cholesterol levels in healthy middle-aged men
    Vogel, RA
    Corretti, MC
    Plotnick, GD
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1996, 77 (01) : 37 - 40
  • [29] Effect of a single high-fat meal on endothelial function in healthy subjects
    Vogel, RA
    Corretti, MC
    Plotnick, GD
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1997, 79 (03) : 350 - 354
  • [30] Williams PL., 1995, GRAYS ANATOMY