Lung morphology: Fast MR imaging assessment with a volumetric interpolated breath-hold technique: Initial experience with patients

被引:55
作者
Biederer, J
Both, M
Graessner, J
Liess, C
Jakob, P
Reuter, M
Heller, M
机构
[1] Univ Hosp Kiel, Dept Diagnost Radiol, D-24105 Kiel 1, Germany
[2] Univ Wurzburg, Dept Phys, D-97070 Wurzburg, Germany
[3] Siemens AG, Hamburg, Germany
关键词
computed tomography (CT); comparative studies; lung; abnormalities; lung neoplasms; CT; MR; magnetic resonance (MR);
D O I
10.1148/radiol.2261011974
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To prospectively evaluate the clinical feasibility of magnetic resonance (MR) imaging of the lungs with fast volumetric interpolated three-dimensional (3D) gradient-recalled-echo (GRE) sequences and to compare this examination with standard computed tomography (CT) in patients with lung abnormalities. MATERIALS AND METHODS: Twenty-five patients with different lung abnormalities were examined with 3D GRE MR imaging. The small pulmonary nodules in seven, TNM stage of large intrapulmonary tumors in eight, and benign bronchial disease in five patients were evaluated. MR imaging-based diagnoses were compared with diagnoses made at CT and at discharge from the hospital. Contingency tables and the McNemar test were used to evaluate the significance of differences between MR imaging- and CT-based diagnoses. RESULTS: The MR imaging- and CT-based diagnoses were identical in 24 of 25 patients. In the remaining patient, clinical findings confirmed the accuracy of the MR imaging finding of pleural empyema. Ten of 15 solid pulmonary nodules smaller than 10 mm in diameter were detected at MR imaging (P > 1) Tumor stages at MR imaging and CT were identical, but lymph node stages at the two examinations differed in two of eight patients owing to overestimation of lymph node size at MR imaging (P >.2). In the five patients with bronchiectasis, MR imaging depicted 26 of 33 affected lung segments; differences between MR imaging and CT findings of bronchial dilatation (P >.05) and bronchial wall thickening (P >.2) were not significant. Peribronchial fibrosis was overestimated at MR imaging owing to image artifacts (P <.05). CONCLUSION: Study results confirmed the feasibility of fast breath-hold 3D GRE MR imaging of the lung. (C) RSNA, 2002.
引用
收藏
页码:242 / 249
页数:8
相关论文
共 30 条
  • [1] MULTISLICE, BREATHHOLD IMAGING OF THE LUNG WITH SUBMILLISECOND ECHO TIMES
    ALSOP, DC
    HATABU, H
    BONNET, M
    LISTERUD, J
    GEFTER, W
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1995, 33 (05) : 678 - 682
  • [2] [Anonymous], 1997, TNM ATLAS ILLUSTRATE
  • [3] Analysis of artefacts and detail resolution of lung MRI with breath-hold T1-weighted gradient-echo and T2-weighted fast spin-echo sequences with respiratory triggering
    Biederer, J
    Reuter, M
    Both, M
    Muhle, C
    Grimm, J
    Graessner, J
    Heller, M
    [J]. EUROPEAN RADIOLOGY, 2002, 12 (02) : 378 - 384
  • [4] Magnetic resonance imaging of the lung with a volumetric interpolated 3D-gradient echo sequence
    Biederer, J
    Graessner, J
    Heller, M
    [J]. ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2001, 173 (10): : 883 - 887
  • [5] BIEDERER J, 2000, MAGMA S1, V11, P263
  • [6] GD-DTPA-POLYLYSINE ENHANCED PULMONARY TIME-OF-FLIGHT MR-ANGIOGRAPHY
    BOCK, JC
    PISON, U
    KAUFMANN, F
    FELIX, R
    [J]. JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1994, 4 (03): : 473 - 476
  • [7] Bremerich J, 2000, J MAGN RESON IMAGING, V11, P622, DOI 10.1002/1522-2586(200006)11:6<622::AID-JMRI8>3.0.CO
  • [8] 2-0
  • [9] Detection of emphysema in rat lungs by using magnetic resonance measurements of 3He diffusion
    Chen, XJ
    Hedlund, LW
    Möller, HE
    Chawla, MS
    Maronpot, RR
    Johnson, GA
    [J]. PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2000, 97 (21) : 11478 - 11481
  • [10] REDUCTION OF PARTIAL-VOLUME ARTIFACTS WITH ZERO-FILLED INTERPOLATION IN 3-DIMENSIONAL MR-ANGIOGRAPHY
    DU, YPP
    PARKER, DL
    DAVIS, WL
    CAO, G
    [J]. JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1994, 4 (05): : 733 - 741