Study on an amperometric immunosensor based on Nafion-cysteine composite membrane for detection of carcinoembryonic antigen

被引:48
作者
Liao, Yuhong [1 ]
Yuan, Ruo [1 ]
Chai, Yaqin [1 ]
Zhuo, Ying [1 ]
Yang, Xia [1 ]
机构
[1] Southwest Univ, Coll Chem & Chem Engn, Minist Educ, Key Lab Luminescence & Real Time Anal, Chongqing 400715, Peoples R China
关键词
Nafion; Cysteine; Nafion-Cys composite membrane; Nano-Au; CEA immunosensor; CEA MONOCLONAL-ANTIBODIES; ZINC-SUPEROXIDE-DISMUTASE; 3RD-GENERATION BIOSENSOR; ELECTRON-TRANSFER; FILMS; GOLD; PHENOSAFRANINE; COPPER; ANION;
D O I
10.1016/j.ab.2010.03.015
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In this work, protonated L-cysteine was entrapped in Nafion (Nf) membrane by cation exchange function, forming Nf-Cys (cysteine) composite membrane, which was more stable, compact, biocompatible, and favorable for mass and electron transfer compared with Nf film solely. Then gold (Au) nanoparticles were adsorbed onto the electrode surface by thiol groups on the composite membrane. After that, nano-Au monolayer was formed, onto which carcinoembryonic antibody was loaded to prepare carcinoembryonic antigen (CEA) immunosensor. The results indicated that the immunosensor had good current response for CEA using potassium ferricyanide as the redox probe. A linear concentration range of 0.01 to 100 ng/ml with a detection limit of 3.3 pg/ml (signal/noise = 3) was observed. Moreover, the morphology of the modified Au substrates was investigated with atomic force microscopy, and the electrochemical properties and performance of modified electrodes were investigated by cyclic voltammograms and electrochemical impendence spectroscopy. The results exhibited that the immunosensor has advantages of simple preparation, high sensitivity, good stability, and long life expectancy. Thus, the method can be used for CEA analysis. (C) 2010 Elsevier Inc. All rights reserved.
引用
收藏
页码:47 / 53
页数:7
相关论文
共 23 条
[1]   ELECTROCHEMISTRY IN HYDROPHOBIC NAFION GELS .1. ELECTROCHEMICAL-BEHAVIOR OF ELECTRODES MODIFIED BY HYDROPHOBIC NAFION GELS LOADED WITH FERROCENES [J].
ANDRIEUX, CP ;
AUDEBERT, P ;
DIVISIABLOHORN, B ;
ALDEBERT, P ;
MICHALAK, F .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1990, 296 (01) :117-128
[2]  
Eisenberg A., 1982, ACS S SERIES, V180
[3]   CONTROLLED NUCLEATION FOR REGULATION OF PARTICLE-SIZE IN MONODISPERSE GOLD SUSPENSIONS [J].
FRENS, G .
NATURE-PHYSICAL SCIENCE, 1973, 241 (105) :20-22
[4]   MEDIATED ELECTROCHEMICAL REDUCTION OF CYTOCHROME-C AND TYROSINASE AT PERFLUOROSULFONATED IONOMER COATED ELECTRODES [J].
FURBEE, JW ;
THOMAS, CR ;
KELLY, RS ;
MALACHOWSKI, MR .
ANALYTICAL CHEMISTRY, 1993, 65 (13) :1654-1657
[5]   Multielectrochromic properties of methylene blue and phenosafranine dyes incorporated into Nafion® film [J].
Ganesan, V ;
John, SA ;
Ramaraj, R .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2001, 502 (1-2) :167-173
[6]   Kinetic and affinity constants of epitope specific anti-carcinoembryonic antigen (CEA) monoclonal antibodies for CEA and engineered CEA domain constructs [J].
Hefta, LJF ;
Neumaier, M ;
Shively, JE .
IMMUNOTECHNOLOGY, 1998, 4 (01) :49-57
[7]   Microenvironment effects on the electrochemical and photoelectrochemical properties of thionine loaded Nafion® films [J].
John, SA ;
Ramaraj, R .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2004, 561 (1-2) :119-126
[8]  
JUN H, 2007, ELECTROCHIM ACTA, V52, P6261
[9]   Redox and ionic-binding switched fluorescence of phenosafranine and thionine included in Nafion® films [J].
Komura, T ;
Niu, GY ;
Yamaguchi, T ;
Asano, M .
ELECTROCHIMICA ACTA, 2003, 48 (06) :631-639
[10]   Amperometric immunosensor for probing complement III (C3) based on immobilizing C3 antibody to a nano-Au monolayer supported by sol-gel-derived carbon ceramic electrode [J].
Lei, CX ;
Yang, Y ;
Wang, H ;
Shen, GL ;
Yu, RQ .
ANALYTICA CHIMICA ACTA, 2004, 513 (02) :379-384