Four-year study of cobalt and chromium blood levels in patients managed with two different metal-on-metal total hip replacements

被引:198
作者
Lhotka, C
Szekeres, T
Steffan, I
Zhuber, K
Zweymüller, K
机构
[1] Municipal Vienna Gersthof Orthopaed Hosp, A-1180 Vienna, Austria
[2] Univ Hosp Vienna, Vienne Gen Hosp, Clin Inst Med & Chem, Diagnost Lab, Vienna, Austria
[3] Univ Vienna, Dept Analyt Chem, Vienna, Austria
[4] Holy Cross Sisters Mercy Hosp, Dept Orthopaed, Wels, Austria
关键词
cobalt; chromium; blood levels; total hip replacements;
D O I
10.1016/S0736-0266(02)00152-3
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Metal-on-metal total hip prostheses will produce a certain amount of wear debris. This results in increased whole-blood metal levels, which may cause adverse effects. It is not known to what extent the problem has been overcome by advances in alloy technology. Methods: In 259 patients who with total hip replacement, blood cobalt and chromium concentrations were measured with atomic absorption spectrophotometry over a period of four years after arthroplasty. Of the patients enrolled in the study, 131 had been managed with a METASUL(R) cobalt-chromium alloy metal-on-metal bearing combination, while 128 had been given a SIKO-MET(R)-SM21(R) cobalt-chromium alloy metal-on-metal combination. The control group consisted of 31 age- and gender-matched subjects. Results: Compared with the controls, all the patients had higher cobalt and chromium levels. Cobalt concentrations were up to 50 times higher, while chromium concentrations were up to 100 times higher. Conclusions: Both systems showed evidence, in the whole-blood samples, of wear debris production by the implants. Therefore, patients managed with metal-on-metal bearing combinations should be carefully monitored in order to ensure that any local or systemic complications are detected early on. (C) 2003 Orthopaedic Research Society. Published by Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:189 / 195
页数:7
相关论文
共 51 条
[1]   METALLIC WEAR IN FAILED TITANIUM-ALLOY TOTAL HIP REPLACEMENTS - A HISTOLOGICAL AND QUANTITATIVE-ANALYSIS [J].
AGINS, HJ ;
ALCOCK, NW ;
BANSAL, M ;
SALVATI, EA ;
WILSON, PD ;
PELLICCI, PM ;
BULLOUGH, PG .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1988, 70A (03) :347-356
[2]  
Amstutz H. C., 1996, CLIN ORTHOP S, V329, P11
[3]  
AMSTUTZ HC, 1996, CLIN ORTHOP S, V329, P297
[4]  
Basle MF, 1996, J BIOMED MATER RES, V30, P157
[5]   HIP-JOINT LOADING DURING WALKING AND RUNNING, MEASURED IN 2 PATIENTS [J].
BERGMANN, G ;
GRAICHEN, F ;
ROHLMANN, A .
JOURNAL OF BIOMECHANICS, 1993, 26 (08) :969-990
[6]  
BETTS F, 1992, CLIN ORTHOP RELAT R, P75
[7]  
Boehler N, 1997, Acta Orthop Belg, V63 Suppl 1, P96
[8]  
BRIEN WW, 1992, CLIN ORTHOP RELAT R, P66
[9]   Elevated serum cobalt with metal-on-metal articulating surfaces [J].
Brodner, W ;
Bitzan, P ;
Meisinger, V ;
Kaider, A ;
GottsaunerWolf, F ;
Kotz, R .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1997, 79B (02) :316-321
[10]   EXCESSIVE METAL RELEASE DUE TO LOOSENING AND FRETTING OF SINTERED PARTICLES ON POROUS-COATED HIP PROSTHESES - REPORT OF 2 CASES [J].
BUCHERT, PK ;
VAUGHN, BK ;
MALLORY, TH ;
ENGH, CA ;
BOBYN, JD .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1986, 68A (04) :606-609