Electroosmotic flow suppressing additives for capillary zone electrophoresis in a hydrodynamically closed separation system

被引:64
作者
Kaniansky, D [1 ]
Masár, M [1 ]
Bielcíková, J [1 ]
机构
[1] Comenius Univ, Fac Nat Sci, Dept Analyt Chem, SK-842015 Bratislava, Slovakia
关键词
electroosmotic flow; buffer composition; hydrodynamically closed separation system; organic acids;
D O I
10.1016/S0021-9673(97)00743-7
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Electroosmotic flow in a hydrodynamically closed capillary zone electrophoresis (CZE) separation compartment must be minimized to achieve high efficiency CZE separations. A group of eight potential electroosmotic flow suppressors was investigated in this context for the separations in fluorinated ethylene-propylene capillary tubes. The suppressors included water soluble methylhydroxyethyl derivatives of cellulose, polyvinylalcohol, polyvinylpyrrolidones and polyethyleneglycols of different molecular masses and Triton X-100. Methylhydroxyethylcellulose derivatives and polyvinylalcohol were found to provide the highest separation efficiencies for a group of model anions when the electroosmotic flow suppressors were used as the carrier electrolyte additives. Using a methylhydroxyethylcellulose coated separation compartment very significant improvements in the separation efficiencies were achieved for polyvinylpyrrolidones and polyethyleneglycols applied in the carrier electrolyte solutions. For example, polyvinylpyrrolidone K 90 applied in this way gave for some of the model analytes the plate height values approaching those estimated in the calculations as theoretical limits for our experimental conditions (H approximate to 3.5 mu m). CZE experiments with albumin and gamma-globulin showed that the use of methylhydroxyethylcellulose derivative in the carrier electrolyte solution at pH=9.2 was effective in eliminating potential disturbances in the separation efficiencies of the analytes due to adsorption of the proteins. (C) 1997 Elsevier Science B.V.
引用
收藏
页码:483 / 494
页数:12
相关论文
共 35 条
[31]   ELECTROPHORESIS IN SYNTHETIC ORGANIC POLYMER CAPILLARIES - VARIATION OF ELECTROOSMOTIC VELOCITY AND ZETA POTENTIAL WITH PH AND SOLVENT COMPOSITION [J].
SCHUTZNER, W ;
KENNDLER, E .
ANALYTICAL CHEMISTRY, 1992, 64 (17) :1991-1995
[32]   SEPARATION OF ALKALI AND ALKALINE-EARTH METAL AND AMMONIUM CATIONS BY CAPILLARY ZONE ELECTROPHORESIS WITH INDIRECT UV ABSORBENCY DETECTION [J].
SIMUNICOVA, E ;
KANIANSKY, D ;
LOKSIKOVA, K .
JOURNAL OF CHROMATOGRAPHY A, 1994, 665 (01) :203-209
[33]   THE PERFORMANCE OF THE UVM-4 UV ANALYZER IN ISOTACHOPHORESIS [J].
TAMCHYNA, J ;
ZUSKA, J ;
VACIK, J .
JOURNAL OF CHROMATOGRAPHY, 1985, 320 (01) :241-244
[34]  
Virtanen R., 1974, ACTA POLYTECH SCAND, V123, P1
[35]   Preparative capillary electrophoresis with wide-bore capillaries [J].
Yin, HF ;
KeelyTemplin, C ;
McManigill, D .
JOURNAL OF CHROMATOGRAPHY A, 1996, 744 (1-2) :45-54