Cellular phone interference with external cardiopulmonary monitoring devices

被引:50
作者
Tri, JL
Hayes, DL
Smith, TT
Severson, RP
机构
[1] Mayo Clin, Telecommun Serv, Rochester, MN 55905 USA
[2] Mayo Clin, Mobile Serv, Rochester, MN 55905 USA
[3] Mayo Clin, Div Cardiovasc Dis & Internal Med, Rochester, MN 55905 USA
[4] Mayo Clin, Sect Equipment Serv, Rochester, MN 55905 USA
关键词
D O I
10.4065/76.1.11
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives: To determine the potential effect (electromagnetic interference) of cellular telephones on external cardiopulmonary monitoring devices. Methods: For this study, we tested 17 different medical devices with 5 portable telephones (4 digital, 1 analog) to assess the potential for electromagnetic interference. The telephones were tested in a normal operating mode to simulate a typical hospital environment with patients or their families using their cellular phones. The medical devices were connected to the appropriate simulators for proper operation while the tests were under way. The screens and alarms of the medical devices were monitored while the telephones were maneuvered in the y and z planes near the devices. Clinically important interference was defined as interference that may hinder interpretation of the data or cause the equipment to malfunction. Results: Any type of interference occurred in 7 (41%) of the 17 devices tested during 54.7 % of the 526 tests. The incidence of clinically important interference was 7.4%, Conclusions: Cellular telephones may interfere with the operation of external cardiopulmonary monitoring devices. However, most of the test results showed that the interference would rarely be clinically important.
引用
收藏
页码:11 / 15
页数:5
相关论文
共 16 条
[1]  
Adler D, 1998, Biomed Instrum Technol, V32, P581
[2]  
Adler David, 1997, Harefuah, V132, P313
[3]  
Bassen HI, 1998, IEEE ENG MED BIOL, V17, P111
[4]  
Carrillo Roger G., 1996, Journal of the American College of Cardiology, V27, p15A
[5]   Interference of cellular phones with implanted permanent pacemakers [J].
Chen, WH ;
Lau, CP ;
Leung, SK ;
Ho, DSW ;
Lee, ISF .
CLINICAL CARDIOLOGY, 1996, 19 (11) :881-886
[6]  
Clifford K J, 1994, Australas Phys Eng Sci Med, V17, P23
[7]   Digital cellular telephone interaction with implantable cardioverter-defibrillators [J].
Fetter, JG ;
Ivans, V ;
Benditt, DG ;
Collins, J .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 31 (03) :623-628
[8]  
Hanada Eisuke, 1998, Biomedical Instrumentation and Technology, V32, P489
[9]   Interference with cardiac pacemakers by cellular telephones [J].
Hayes, DL ;
Wang, PJ ;
Reynolds, DW ;
Estes, NAM ;
Griffith, JL ;
Steffens, RA ;
Carlo, GL ;
Findlay, GK ;
Johnson, CM .
NEW ENGLAND JOURNAL OF MEDICINE, 1997, 336 (21) :1473-1479
[10]   Influence of mobile phones on life-saving and life-support systems [J].
Irnich, W ;
Tobisch, R .
BIOMEDIZINISCHE TECHNIK, 1998, 43 (06) :164-173