Interference of cellular phones with implanted permanent pacemakers

被引:15
作者
Chen, WH
Lau, CP
Leung, SK
Ho, DSW
Lee, ISF
机构
[1] UNIV HONG KONG,QUEEN MARY HOSP,DEPT MED,DIV CARDIOL,HONG KONG,HONG KONG
[2] KWONG WAH HOSP,HONG KONG,HONG KONG
关键词
pacemaker; interference; cellular phone;
D O I
10.1002/clc.4960191108
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background and hypothesis: Occasional reports have suggested that cellular phones may interfere with permanent pacemakers. Our investigation sought to determine systematically the effects of commercially available cellular phones on the performances of different pacing modes and sensing lead configurations of permanent implanted pacemakers. Methods: We conducted the study in 29 patients implanted with single- or dual-chamber bipolar rate-adaptive permanent pacemakers (a total of nine different models and six different sensors: minute ventilation, activity sensing using either accelerometer or piezoelectric crystal, QT and oxygen saturation sensing) from four different manufacturers. Three different cellular phones with analog or digital coding with maximum power from 0.6 to 2 W were used to assess the effect of pacemaker interference. Each cellular phone was positioned at (1) above the pacemaker pocket, (2) the ear level ipsilateral to the pacemaker pocket, and (3) the contralateral ear level. Surface electrocardiograms, intracardiac electrograms, and marker channels were recorded where possible during the following maneuvers at each position: (1) calls made by a stationary phone to a cellular phone, and (2) calls made from the cellular phone to a stationary phone. A total of eight different pacing modes [DDD(R), VDD(R), AAI(R) and VVI(R)] in both unipolar and bipolar sensing configurations was tested. Results: Interference was demonstrated during cellular phone operation in 74 of 2,418 (3.1%) episodes in eight patients. Three types of interference were observed: inhibition of pacing output, rapid ventricular tracking in DDD(R) or VDD(R) mode, and asynchronous pacing. All were observed only with the cellular phone positioned above the pacemaker pocket. Interference occurred prior to and after the termination of the ringing tone of the cellular phone in 57% of cases. Cellular phones with either digital or analog technology could cause interference. Unipolar atrial lead was most susceptible to interference (relative frequency of interference: unipolar 1.8%, bipolar 0.4%, p<0.05; atrial 2.9%, ventricular 1%, p<0.05). There was no sensor-driven rate acceleration during all tests. In all patients, reprogramming of the sensitivity level successfully prevented cellular phone interference. Conclusions: Commercially available cellular phones can cause reversible interference to implanted single- or dual-chamber permanent pacemakers. The effect is maximal with high atrial unipolar sensitivity, especially in single pass VDD(R) systems. Both digital and analog cellular phones can lead to interference. Pacemaker interference can occur prior to a warning sign (ringing tone) of the phone and may have significant implications in patient safety.
引用
收藏
页码:881 / 886
页数:6
相关论文
共 14 条
[1]   DO EUROPEAN GSM MOBILE CELLULAR PHONES POSE A POTENTIAL RISK TO PACEMAKER PATIENTS [J].
BARBARO, V ;
BARTOLINI, P ;
DONATO, A ;
MILITELLO, C ;
ALTAMURA, G ;
AMMIRATI, F ;
SANTINI, M .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1995, 18 (06) :1218-1224
[2]  
CARRILLO R, 1995, PACE PACING CLIN ELE, V18, P863
[3]   INITIAL EXPERIENCE WITH A NEW SINGLE CHAMBER, DUAL SENSOR RATE-RESPONSIVE PACEMAKER [J].
CONNELLY, DT .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1993, 16 (09) :1833-1841
[4]  
HAYES DL, 1995, PACE, V18, P842
[5]  
HAYES DL, 1995, PACE PACING CLIN ELE, V18, P863
[6]  
IRNICH W, 1985, MODERN CARDIAC PACIN, P839
[7]   RATE-ADAPTIVE CARDIAC PACING USING RIGHT-VENTRICULAR VENOUS OXYGEN-SATURATION - QUANTIFICATION OF CHRONOTROPIC BEHAVIOR DURING DAILY ACTIVITIES AND MAXIMAL EXERCISE [J].
LAU, CP ;
TAI, YT ;
LEUNG, WH ;
LEUNG, SK ;
LI, TPS ;
WONG, CK ;
LEE, ISF ;
YERICH, C ;
ERICKSON, M .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1994, 17 (12) :2236-2246
[8]   THE RANGE OF SENSORS AND ALGORITHMS USED IN RATE ADAPTIVE CARDIAC PACING [J].
LAU, CP .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1992, 15 (08) :1177-1211
[9]   ATRIAL ARRHYTHMIA MANAGEMENT WITH SENSOR CONTROLLED ATRIAL REFRACTORY PERIOD AND AUTOMATIC-MODE SWITCHING IN PATIENTS WITH MINUTE VENTILATION SENSING DUAL CHAMBER RATE ADAPTIVE PACEMAKERS [J].
LAU, CP ;
TAI, YT ;
FONG, PC ;
LI, JPS ;
CHUNG, FLW .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1992, 15 (10) :1504-1514
[10]  
Moberg BL, 1995, EUR JCPE, V5, P146