THE RANGE OF SENSORS AND ALGORITHMS USED IN RATE ADAPTIVE CARDIAC PACING

被引:44
作者
LAU, CP
机构
[1] Division of Cardiology, Department of Medicine, University of Hong Kong, Queen Mary Hospital
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 1992年 / 15卷 / 08期
关键词
SENSORS; ALGORITHMS; RATE ADAPTIVE PACING; SENSOR COMBINATION;
D O I
10.1111/j.1540-8159.1992.tb03121.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Implantable sensors play an important role in physiological cardiac pacing. Sensors can be classified according to the technical methods in which sensing is achieved: the sensing of the evoked ventricular response, intrathoracic impedance and body acceleration forces, and the incorporation of special sensors on pacing electrodes. These sensors differ in their relative merits in terms of speed, proportionality, sensitivity, and specificity of rate response. The efficacy of a sensor can be significantly modified by the algorithm used in relating sensor signal to a pacing rate change. The currently available types of sensors and algorithms are summarized and compared in this review article. The relative merits of these sensors and algorithms form the basis for designing a multisensor pacing system.
引用
收藏
页码:1177 / 1211
页数:35
相关论文
共 192 条
[1]  
ALT E, 1987, PACE, V10, P1206
[2]   THE BASIS FOR ACTIVITY CONTROLLED RATE VARIABLE CARDIAC-PACEMAKERS - AN ANALYSIS OF MECHANICAL FORCES ON THE HUMAN-BODY INDUCED BY EXERCISE AND ENVIRONMENT [J].
ALT, E ;
MATULA, M ;
THERES, H ;
HEINZ, M ;
BAKER, R .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1989, 12 (10) :1667-1680
[3]   CONTROL OF PACEMAKER RATE BY IMPEDANCE-BASED RESPIRATORY MINUTE VENTILATION [J].
ALT, E ;
HEINZ, M ;
HIRGSTETTER, C ;
EMSLANDER, HP ;
DAUM, S ;
BLOMER, H .
CHEST, 1987, 92 (02) :247-252
[4]   RATE CONTROL OF PHYSIOLOGICAL PACEMAKERS BY CENTRAL VENOUS-BLOOD TEMPERATURE [J].
ALT, E ;
HIRGSTETTER, C ;
HEINZ, M ;
BLOMER, H .
CIRCULATION, 1986, 73 (06) :1206-1212
[5]   A NEW RATE-MODULATED PACEMAKER SYSTEM OPTIMIZED BY COMBINATION OF 2 SENSORS [J].
ALT, E ;
THERES, H ;
HEINZ, M ;
MATULA, M ;
THILO, R ;
BLOMER, H .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1988, 11 (08) :1119-1129
[6]   A NEW MECHANICAL SENSOR FOR DETECTING BODY ACTIVITY AND POSTURE, SUITABLE FOR RATE RESPONSIVE PACING [J].
ALT, E ;
MATULA, M ;
THILO, R ;
THERES, H ;
HEINZ, M ;
BLOMER, H .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1988, 11 (11) :1875-1881
[7]  
ALT E, 1991, Patent No. 5003976
[8]  
ALT E, 1988, J ELECTROPHYSIOL, V2, P508
[9]  
ALT E, 1990, RBM, V12, P32
[10]  
ANDERSON K, 1983, PACE, V6, pA12