THE RANGE OF SENSORS AND ALGORITHMS USED IN RATE ADAPTIVE CARDIAC PACING

被引:44
作者
LAU, CP
机构
[1] Division of Cardiology, Department of Medicine, University of Hong Kong, Queen Mary Hospital
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 1992年 / 15卷 / 08期
关键词
SENSORS; ALGORITHMS; RATE ADAPTIVE PACING; SENSOR COMBINATION;
D O I
10.1111/j.1540-8159.1992.tb03121.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Implantable sensors play an important role in physiological cardiac pacing. Sensors can be classified according to the technical methods in which sensing is achieved: the sensing of the evoked ventricular response, intrathoracic impedance and body acceleration forces, and the incorporation of special sensors on pacing electrodes. These sensors differ in their relative merits in terms of speed, proportionality, sensitivity, and specificity of rate response. The efficacy of a sensor can be significantly modified by the algorithm used in relating sensor signal to a pacing rate change. The currently available types of sensors and algorithms are summarized and compared in this review article. The relative merits of these sensors and algorithms form the basis for designing a multisensor pacing system.
引用
收藏
页码:1177 / 1211
页数:35
相关论文
共 192 条
[71]   ACTIVITY-SENSING, RATE-RESPONSIVE PACING - IMPROVEMENT IN MYOCARDIAL PERFORMANCE WITH EXERCISE [J].
HUMEN, DP ;
KOSTUK, WJ ;
KLEIN, GJ .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1985, 8 (01) :52-59
[72]  
IONESCU VL, 1980, PACE, V3, P375
[73]   A RATE-RESPONSIVE PACEMAKER CONTROLLED BY RIGHT VENTRICULAR BLOOD TEMPERATURE [J].
JOLGREN, D ;
FEARNOT, N ;
GEDDES, L .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1984, 7 (05) :794-801
[74]   CATECHOLAMINE LEVELS AND PACING BEHAVIOR OF QT-DRIVEN PACEMAKERS DURING EXERCISE [J].
JORDAENS, L ;
BACKERS, J ;
MOERMAN, E ;
CLEMENT, DL .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1990, 13 (05) :603-607
[75]   BEHAVIOR OF A RESPIRATORY DRIVEN PACEMAKER AND DIRECT RESPIRATORY MEASUREMENTS [J].
JORDAENS, L ;
BERGHMANS, L ;
VANWASSENHOVE, E ;
CLEMENT, DL .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1989, 12 (10) :1600-1606
[76]  
KARLOF I, 1975, ACTA MED SCAND, V197, P195
[77]   RATE-MODULATED CARDIAC PACING BASED ON TRANS-THORACIC IMPEDANCE MEASUREMENTS OF MINUTE VENTILATION - CORRELATION WITH EXERCISE GAS-EXCHANGE [J].
KAY, GN ;
BUBIEN, RS ;
EPSTEIN, AE ;
PLUMB, VJ .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1989, 14 (05) :1283-1289
[78]  
KIEL EA, 1987, CLIN RES, V35, pA51
[79]  
KNUDSON MB, 1982, ADV TECHNOLOGY CLIN, P249
[80]   VENTILATORY RESPONSES TO METABOLIC-ACIDOSIS OF TREADMILL AND CYCLE ERGOMETRY [J].
KOYAL, SN ;
WHIPP, BJ ;
HUNTSMAN, D ;
BRAY, GA ;
WASSERMAN, K .
JOURNAL OF APPLIED PHYSIOLOGY, 1976, 40 (06) :864-867