INITIAL EXPERIENCE WITH A NEW SINGLE CHAMBER, DUAL SENSOR RATE-RESPONSIVE PACEMAKER

被引:21
作者
CONNELLY, DT
机构
[1] Cardiothoracic Centre, Liverpool
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 1993年 / 16卷 / 09期
关键词
SENSOR BLENDING; SENSOR CROSSING; DUAL SENSOR RATE RESPONSIVE PACEMAKER;
D O I
10.1111/j.1540-8159.1993.tb01818.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
In August 1991, a new single chamber pacemaker became available that utilizes information from two sensors, activity and stimulus-to-T wave (QT) interval. We are reporting on the first 90 implants in 21 centers. T wave sensing was adequate at implantation in 88/90 patients, with a safety margin of > 100% in 86/90. Activity sensing was adequate in all patients. The contribution of each sensor (sensor blending) is programmable for each patient. Of 75 patients assessed at 1 month after implant, three have been programmed to ''Activity-Only'' mode, and 72 to dual sensor mode. Of these, 18 have been programmed to ''QT < Activity,'' 48 to ''QT = Activity,'' and 6 to ''QT > Activity.'' Forty-five patients underwent exercise testing in dual sensor mode and a subgroup of 15 also underwent exercise testing in Activity-Only mode. The dual sensor mode produced a more gradual increase in pacing rate. Sensor Cross Checking(TM) satisfactorily prevented a sustained high pacing rate in tests of false-positive activity sensing (tapping, vibrating pacemaker, or static pressure). The maximum pacing rate on walking downstairs (94.2 +/- 7.2 ppm) was similar to that produced by walking upstairs (91.6 +/- 5.9 ppm). We conclude that initial assessment of this dual sensor, single chamber, rate responsive pacemaker confirms that the algorithm for combining data from two sensors functions satisfactorily. Dual sensor rate responsive pacing may offer significant advantages over single sensor devices, and further studies of this novel device are indicated.
引用
收藏
页码:1833 / 1841
页数:9
相关论文
共 27 条
[1]   A NEW RATE-MODULATED PACEMAKER SYSTEM OPTIMIZED BY COMBINATION OF 2 SENSORS [J].
ALT, E ;
THERES, H ;
HEINZ, M ;
MATULA, M ;
THILO, R ;
BLOMER, H .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1988, 11 (08) :1119-1129
[2]   ONE-YEAR FOLLOW-UP OF AUTOMATIC ADAPTATION OF THE RATE RESPONSE ALGORITHM OF THE QT SENSING, RATE ADAPTIVE PACEMAKER [J].
BAIG, MW ;
BOUTE, W ;
BEGEMANN, M ;
PERRINS, EJ .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1991, 14 (11) :1598-1605
[3]   COMPARATIVE-EVALUATION OF RATE MODULATION IN NEW GENERATION EVOKED QT AND ACTIVITY SENSING PACEMAKERS [J].
BELLAMY, CM ;
ROBERTS, DH ;
HUGHES, S ;
CHARLES, RG .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1992, 15 (07) :993-999
[4]   SINGLE-CHAMBER CARDIAC PACING WITH ACTIVITY-INITIATED CHRONOTROPIC RESPONSE - EVALUATION BY CARDIOPULMONARY EXERCISE TESTING [J].
BENDITT, DG ;
MIANULLI, M ;
FETTER, J ;
BENSON, DW ;
DUNNIGAN, A ;
MOLINA, E ;
GORNICK, CC ;
ALMQUIST, A .
CIRCULATION, 1987, 75 (01) :184-191
[5]   RELIABILITY OF EVOKED ENDOCARDIAL T-WAVE SENSING IN 1,500 PACEMAKER PATIENTS [J].
BOUTE, W ;
DERRIEN, Y ;
WITTKAMPF, FHM .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1986, 9 (06) :948-953
[6]   ACTIVITY-SENSING RATE RESPONSIVE VERSUS CONVENTIONAL FIXED-RATE PACING - A COMPARISION OF RATE BEHAVIOR AND PATIENT WELL-BEING DURING ROUTINE DAILY EXERCISE [J].
CANDINAS, RA ;
GLOOR, HO ;
AMANN, FW ;
SCHOENBECK, M ;
TURINA, M .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1991, 14 (02) :204-213
[7]  
DENDULK K, 1991, PACE, V14, P660
[8]   INITIAL EXPERIENCE WITH A PHYSIOLOGICAL, RATE RESPONSIVE PACEMAKER [J].
DONALDSON, RM ;
FOX, K ;
RICKARDS, AF .
BRITISH MEDICAL JOURNAL, 1983, 286 (6366) :667-671
[9]   RATE-MODULATED PACING [J].
FURMAN, S .
CIRCULATION, 1990, 82 (04) :1081-1094
[10]   STANDARDIZED INFORMAL EXERCISE TESTING FOR PROGRAMMING RATE ADAPTIVE PACEMAKERS [J].
HAYES, DL ;
VONFELDT, L ;
HIGANO, ST .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1991, 14 (11) :1772-1776