Multicomponent titration of calcium plus magnesium mixtures employing a potentiometric electronic-tongue

被引:5
作者
Calvo, Daniel [1 ]
Bartroli, Jordi [1 ]
del Valle, Manuel [1 ]
机构
[1] Univ Barcelona, Sensors & Biosensors Grp, Chem Dept, Bellaterra 08193, Spain
关键词
potentiometric titration; electronic tongue; ion selective electrode; artificial neural network; calcium; magnesium;
D O I
10.1080/00032710701380780
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A fast novel potentiometric titration procedure is proposed, in which the detection system is formed by a potentiometric electronic tongue. The titration consists in a reduced number of fixed titrant additions to the sample and the recording of the potentials of an array of Ion Selective Electrodes. The obtained data matrix is entered to an Artificial Neural Network response model, previously trained to furnish concentrations of a multicomponent mixture. The principle is demonstrated with automated EDTA titration of mixtures of Ca2+ and Mg2+ at fixed pH 8.5. In this case, five 2 ml fixed volume additions plus the readings of four sensors were adequate for the resolution of the mixture. In the conditions used, titration was feasible up to 3.3 mM total ion concentration, the precision was estimated as 3.20% RSD for Ca2+ and 2.76% RSD for Mg2+ (n = 5), and the detection limits 0.16 mM Ca2+ and 0.26 mM Mg2+. The procedure was applied to mineral waters and compared with reference methods (correlation = 0.92 for Ca2+ and correlation 0.89 for Mg2+, n = 14).
引用
收藏
页码:1579 / 1595
页数:17
相关论文
共 33 条
[21]   Tweezer-type neutral carrier-based calcium-selective membrane electrode with drastically reduced anionic interference [J].
Lee, MH ;
Yoo, CL ;
Lee, JS ;
Cho, IS ;
Kim, BH ;
Cha, GS ;
Nam, H .
ANALYTICAL CHEMISTRY, 2002, 74 (11) :2603-2607
[22]   Multicomponent analysis of Korean green tea by means of disposable all-solid-state potentiometric electronic tongue microsystem [J].
Lvova, L ;
Legin, A ;
Vlasov, Y ;
Cha, GS ;
Nam, H .
SENSORS AND ACTUATORS B-CHEMICAL, 2003, 95 (1-3) :391-399
[23]  
Moisio T, 1996, FRESEN J ANAL CHEM, V354, P271
[24]   EXTENDED SENSITIVITY FOR THE CALCIUM SELECTIVE ELECTRODE [J].
MORTON, RW ;
CHUNG, JK ;
MILLER, JL ;
CHARLTON, JP ;
FAGER, RS .
ANALYTICAL BIOCHEMISTRY, 1986, 157 (02) :345-352
[25]   Simultaneous determination of mixtures of acids by potentiometric titration [J].
Ni, YN .
ANALYTICA CHIMICA ACTA, 1998, 367 (1-3) :145-152
[26]   DETERMINATION OF MIXED-METAL IONS BY COMPLEXOMETRIC TITRATION AND NONLINEAR PARTIAL LEAST-SQUARES CALIBRATION [J].
NI, YN ;
PENG, ZH .
ANALYTICA CHIMICA ACTA, 1995, 304 (02) :217-222
[27]   Application of artificial neural network to simultaneous potentiometric determination of silver(I), mercury(II) and copper(II) ions by an unmodified carbon paste electrode [J].
Shamsipur, M ;
Tashkhourian, J ;
Hemmateenejad, B ;
Sharghi, H .
TALANTA, 2004, 64 (03) :590-596
[28]   Multicomponent acid-base titration by principal component-artificial neural network calibration [J].
Shamsipur, M ;
Hemmateenejad, B ;
Akhond, M .
ANALYTICA CHIMICA ACTA, 2002, 461 (01) :147-153
[29]   ION-SELECTIVE ELECTRODES BASED ON NATURAL CARBOXYLIC POLYETHER ANTIBIOTICS [J].
SUZUKI, K ;
TOHDA, K ;
ARUGA, H ;
MATSUZOE, M ;
INOUE, H ;
SHIRAI, T .
ANALYTICAL CHEMISTRY, 1988, 60 (17) :1714-1721
[30]  
UMEZAWA K, 1990, HDB IONSELECTIVE ELE