Changes of hemorheological and biochemical parameters after plasma perfusion using a tryptophan-polyvinyl alcohol adsorber leading to clinical improvement in patients suffering from maculopathy

被引:10
作者
Widder, RA [1 ]
Brunner, R [1 ]
Engels, B [1 ]
Borberg, H [1 ]
Oette, K [1 ]
机构
[1] Univ Cologne, Augenklin, Dept Ophthalmol, D-50924 Cologne, Germany
关键词
plasmapheresis methods; immunosorbent techniques; rheology; blood viscosity; erythrocyte aggregation; macular degeneration therapy; macular edema therapy;
D O I
10.1159/000014308
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Selective adsorption is an extracorporeal treatment able to reduce high-molecular-weight proteins and lipids. We evaluated its efficacy in lowering hemorheological parameters to achieve a better microcirculation of the retina. Patients and Methods: Ten patients suffering from maculopathies of various origin underwent a selective plasma adsorption procedure using the TR-350. Plasma and whole blood viscosity, erythrocyte aggregation and proteins and lipids were determined before and 24 h after therapy. Results: Selective adsorption therapy reduced the high-molecular-weight proteins and lipids. Plasma viscosity, standardized whole blood viscosity and erythrocyte aggregation were significantly lowered to 87, 88 and 65%, respectively, of their values prior to treatment. An improvement of visual acuity was achieved in 6/10 patients. Minor side effects were noted in 2/10 patients. Conclusions: Selective adsorption using the TR-350 adsorber is a safe technique, showing a high impact on blood theology. The changes of hemorheological parameters led to clinical improvement in 6/10 patients suffering from retinal disorders.
引用
收藏
页码:15 / 21
页数:7
相关论文
共 34 条
[11]  
ERNST E, 1987, LANCET, V1, P1449
[12]   The viscosity of the blood in narrow capillary tubes [J].
Fahraeus, R ;
Lindqvist, T .
AMERICAN JOURNAL OF PHYSIOLOGY, 1931, 96 (03) :562-568
[13]   NEW VISUAL-ACUITY CHARTS FOR CLINICAL RESEARCH [J].
FERRIS, FL ;
KASSOFF, A ;
BRESNICK, GH ;
BAILEY, I .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1982, 94 (01) :91-96
[14]  
FUCHS M, 1990, INFUSIONSTHERAPIE, V17, P205
[15]  
GUSTAFSSON L, 1981, AM J PHYSIOL, V241, P513
[16]  
HARKNESS J, 1971, Biorheology, V8, P171
[17]  
Heinen A, 1984, Fortschr Ophthalmol, V81, P444
[18]  
HUESTIS DW, 1983, LANCET, V1, P1043
[19]   ADSORPTION PROFILE OF COMMERCIALLY AVAILABLE ADSORBENTS - AN INVITRO EVALUATION [J].
IKONOMOV, V ;
SAMTLEBEN, W ;
SCHMIDT, B ;
BLUMENSTEIN, M ;
GURLAND, HJ .
INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1992, 15 (05) :312-319
[20]   MINI ERYTHROCYTE AGGREGOMETER - A NEW APPARATUS FOR RAPID QUANTIFICATION OF THE EXTENT OF ERYTHROCYTE AGGREGATION [J].
KIESEWETTER, H ;
RADTKE, H ;
SCHNEIDER, R ;
MUSSLER, K ;
SCHEFFLER, A ;
SCHMIDSCHONBEIN, H .
BIOMEDIZINISCHE TECHNIK, 1982, 27 (09) :209-213