Label-free electrochemical detection of DNA in blood serum via target-induced resolution of an electrode-bound DNA pseudoknot

被引:228
作者
Xiao, Yi
Qu, Xiaogang
Plaxco, Kevin W. [1 ]
Heeger, Alan J.
机构
[1] Chinese Acad Sci, Changchun Inst Appl Chem, Div Biol Inorgan Chem, Key Lab Rare Earth Chem & Phys, Changchun 130022, Jilin, Peoples R China
[2] Univ Calif Santa Barbara, Dept Phys, Santa Barbara, CA 93106 USA
[3] Univ Calif Santa Barbara, Inst Polymers & Organ Solids, Dept Chem & Biochem, Santa Barbara, CA 93106 USA
[4] Univ Calif Santa Barbara, Program BioMol Sci & Engn, Santa Barbara, CA 93106 USA
关键词
D O I
10.1021/ja074218y
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
We have demonstrated a fully covalent, signal-on E-DNA architecture based on the target-induced resolution of a DNA pseudokont. In the absence of target, the electrode-bound DNA probe adopts a pseudoknot conformation that segregates an attached methylene blue (MB) from the electrode. Upon target binding, the pseudoknot is resolved, leading to the formation of a single-stranded DNA element that supports electron transfer from the methylene blue to the electrode.
引用
收藏
页码:11896 / +
页数:3
相关论文
共 17 条
[1]   CHARACTERIZATION OF AN EFFICIENT CORONAVIRUS RIBOSOMAL FRAMESHIFTING SIGNAL - REQUIREMENT FOR AN RNA PSEUDOKNOT [J].
BRIERLEY, I ;
DIGARD, P ;
INGLIS, SC .
CELL, 1989, 57 (04) :537-547
[2]   Electrochemical DNA sensors [J].
Drummond, TG ;
Hill, MG ;
Barton, JK .
NATURE BIOTECHNOLOGY, 2003, 21 (10) :1192-1199
[3]   Electrochemical interrogation of conformational changes as a reagentless method for the sequence-specific detection of DNA [J].
Fan, CH ;
Plaxco, KW ;
Heeger, AJ .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2003, 100 (16) :9134-9137
[4]   DNA-PEG-DNA triblock macromolecules for reagentless DNA detection [J].
Immoos, CE ;
Lee, SJ ;
Grinstaff, MW .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2004, 126 (35) :10814-10815
[5]   Conformationally gated electrochemical gene detection [J].
Immoos, CE ;
Lee, SJ ;
Grinstaff, MW .
CHEMBIOCHEM, 2004, 5 (08) :1100-1103
[6]   Electroanalytical and bioelectroanalytical systems based on metal and semiconductor nanoparticles [J].
Katz, E ;
Willner, I ;
Wang, J .
ELECTROANALYSIS, 2004, 16 (1-2) :19-44
[7]   Electrochemistry of methylene blue bound to a DNA-modified electrode [J].
Kelley, SO ;
Barton, JK ;
Jackson, NM ;
Hill, MG .
BIOCONJUGATE CHEMISTRY, 1997, 8 (01) :31-37
[8]   Comparison of the signaling and stability of electrochemical DNA sensors fabricated from 6-or 11-carbon self-assembled monolayers [J].
Lai, Rebecca Y. ;
Seferos, Dwight S. ;
Heeger, Alan J. ;
Bazan, Guillermo C. ;
Plaxco, Kevin W. .
LANGMUIR, 2006, 22 (25) :10796-10800
[9]   Using self-assembly to control the structure of DNA monolayers on gold: A neutron reflectivity study [J].
Levicky, R ;
Herne, TM ;
Tarlov, MJ ;
Satija, SK .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1998, 120 (38) :9787-9792
[10]   Sequence-specific, electronic detection of oligonucleotides in blood, soil, and foodstuffs with the reagentless, reusable E-DNA sensor [J].
Lubin, Arica A. ;
Lai, Rebecca Y. ;
Baker, Brian R. ;
Heeger, Alan J. ;
Plaxco, Kevin W. .
ANALYTICAL CHEMISTRY, 2006, 78 (16) :5671-5677