Pulmonary nodules on multi-detector row CT scans: Performance comparison of radiologists and computer-aided detection

被引:211
作者
Rubin, GD
Lyo, JK
Paik, DS
Sherbondy, AJ
Chow, LC
Leung, AN
Mindelzun, R
Schraedley-Desmond, PK
Zinck, SE
Naidich, DP
Napel, S
机构
[1] Stanford Univ, Sch Med, Dept Radiol, Stanford, CA 94305 USA
[2] Stanford Univ, Sch Med, Dept Elect Engn, Stanford, CA 94305 USA
[3] NYU, Sch Med, Dept Radiol, New York, NY USA
关键词
D O I
10.1148/radiol.2341040589
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To compare the performance of radiologists and of a computer-aided detection (CAD) algorithm for pulmonary nodule detection on thin-section thoracic computed tomographic (CT) scans. MATERIALS AND METHODS: The study was approved by the institutional review board. The requirement of informed consent was waived. Twenty outpatients (age range, 15-91 years; mean, 64 years) were examined with chest CT (multi-detector row scanner, four detector rows, 1.25-mm section thickness, and 0.6-mm interval) for pulmonary nodules. Three radiologists independently analyzed CT scans, recorded the locus of each nodule candidate, and assigned each a confidence score. A CAD algorithm with parameters chosen by using cross validation was applied to the 20 scans. The reference standard was established by two experienced thoracic radiologists in consensus, with blind review of all nodule candidates and free search for additional nodules at a dedicated workstation for three-dimensional image analysis. True-positive (TP) and false-positive (FP) results and confidence levels were used to generate free-response receiver operating characteristic (ROC) plots. Double-reading performance was determined on the basis of TP detections by either reader. RESULTS: The 20 scans showed 195 noncalcified nodules with a diameter of 3 mm or more (reference reading). Area under the alternative free-response ROC curve was 0.54, 0.48, 0.55, and 0.36 for CAD and readers 1-3, respectively. Differences between reader 3 and CAD and between readers 2 and 3 were significant (P < .05); those between CAD and readers 1 and 2 were not significant. Mean sensitivity for individual readings was 50% (range, 41%-60%); double reading resulted in increase to 63% (range, 56%-67%). With CAD used at a threshold allowing only three FP detections per CT scan, mean sensitivity was increased to 76% (range, 73%-78%). CAD complemented individual readers by detecting additional nodules more effectively than did a second reader; CAD-reader weighted K values were significantly lower than reader-reader weighted K values (Wilcoxon rank sum test, P < .05). CONCLUSION: With CAD used at a level allowing only three FP detections per CT scan, sensitivity was substantially higher than with conventional double reading. (C) RSNA, 2004.
引用
收藏
页码:274 / 283
页数:10
相关论文
共 44 条
  • [1] Transxiphoid video-assisted pulmonary metastasectomy: Relevance of helical computed tomography occult lesions
    Ambrogi, V
    Paci, M
    Pompeo, E
    Mineo, TC
    [J]. ANNALS OF THORACIC SURGERY, 2000, 70 (06) : 1847 - 1852
  • [2] THE EFFICACY OF DOUBLE READING MAMMOGRAMS IN BREAST SCREENING
    ANDERSON, EDC
    MUIR, BB
    WALSH, JS
    KIRKPATRICK, AE
    [J]. CLINICAL RADIOLOGY, 1994, 49 (04) : 248 - 251
  • [3] Computerized detection of pulmonary nodules on CT scans
    Armato, SG
    Giger, ML
    Moran, CJ
    Blackburn, JT
    Doi, K
    MacMahon, H
    [J]. RADIOGRAPHICS, 1999, 19 (05) : 1303 - 1311
  • [4] Lung cancer: Performance of automated lung nodule detection applied to cancers missed in a CT screening program
    Armato, SG
    Li, F
    Giger, ML
    MacMahon, H
    Sone, S
    Doi, K
    [J]. RADIOLOGY, 2002, 225 (03) : 685 - 692
  • [5] Automated detection of lung nodules in CT scans: Preliminary results
    Armato, SG
    Giger, ML
    MacMahon, H
    [J]. MEDICAL PHYSICS, 2001, 28 (08) : 1552 - 1561
  • [6] Effect of human variability on independent double: Reading in screening mammography
    Beam, CA
    Sullivan, DC
    Layde, PM
    [J]. ACADEMIC RADIOLOGY, 1996, 3 (11) : 891 - 897
  • [7] Patient-specific models for lung nodule detection and surveillance in CT images
    Brown, MS
    McNitt-Gray, MF
    Goldin, JG
    Suh, RD
    Sayre, JW
    Aberle, DR
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2001, 20 (12) : 1242 - 1250
  • [8] Lung micronodules: Automated method for detection at thin-section CT - Initial experience
    Brown, MS
    Goldin, JG
    Suh, RD
    McNitt-Gray, MF
    Sayre, JW
    Aberle, DR
    [J]. RADIOLOGY, 2003, 226 (01) : 256 - 262
  • [9] Statistical power in observer-performance studies: Comparison of the receiver operating characteristic and free-response methods in tasks involving localization
    Chakraborty, D
    [J]. ACADEMIC RADIOLOGY, 2002, 9 (02) : 147 - 156
  • [10] MAXIMUM-LIKELIHOOD ANALYSIS OF FREE-RESPONSE RECEIVER OPERATING CHARACTERISTIC (FROC) DATA
    CHAKRABORTY, DP
    [J]. MEDICAL PHYSICS, 1989, 16 (04) : 561 - 568