Pulmonary nodules on multi-detector row CT scans: Performance comparison of radiologists and computer-aided detection

被引:211
作者
Rubin, GD
Lyo, JK
Paik, DS
Sherbondy, AJ
Chow, LC
Leung, AN
Mindelzun, R
Schraedley-Desmond, PK
Zinck, SE
Naidich, DP
Napel, S
机构
[1] Stanford Univ, Sch Med, Dept Radiol, Stanford, CA 94305 USA
[2] Stanford Univ, Sch Med, Dept Elect Engn, Stanford, CA 94305 USA
[3] NYU, Sch Med, Dept Radiol, New York, NY USA
关键词
D O I
10.1148/radiol.2341040589
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To compare the performance of radiologists and of a computer-aided detection (CAD) algorithm for pulmonary nodule detection on thin-section thoracic computed tomographic (CT) scans. MATERIALS AND METHODS: The study was approved by the institutional review board. The requirement of informed consent was waived. Twenty outpatients (age range, 15-91 years; mean, 64 years) were examined with chest CT (multi-detector row scanner, four detector rows, 1.25-mm section thickness, and 0.6-mm interval) for pulmonary nodules. Three radiologists independently analyzed CT scans, recorded the locus of each nodule candidate, and assigned each a confidence score. A CAD algorithm with parameters chosen by using cross validation was applied to the 20 scans. The reference standard was established by two experienced thoracic radiologists in consensus, with blind review of all nodule candidates and free search for additional nodules at a dedicated workstation for three-dimensional image analysis. True-positive (TP) and false-positive (FP) results and confidence levels were used to generate free-response receiver operating characteristic (ROC) plots. Double-reading performance was determined on the basis of TP detections by either reader. RESULTS: The 20 scans showed 195 noncalcified nodules with a diameter of 3 mm or more (reference reading). Area under the alternative free-response ROC curve was 0.54, 0.48, 0.55, and 0.36 for CAD and readers 1-3, respectively. Differences between reader 3 and CAD and between readers 2 and 3 were significant (P < .05); those between CAD and readers 1 and 2 were not significant. Mean sensitivity for individual readings was 50% (range, 41%-60%); double reading resulted in increase to 63% (range, 56%-67%). With CAD used at a threshold allowing only three FP detections per CT scan, mean sensitivity was increased to 76% (range, 73%-78%). CAD complemented individual readers by detecting additional nodules more effectively than did a second reader; CAD-reader weighted K values were significantly lower than reader-reader weighted K values (Wilcoxon rank sum test, P < .05). CONCLUSION: With CAD used at a level allowing only three FP detections per CT scan, sensitivity was substantially higher than with conventional double reading. (C) RSNA, 2004.
引用
收藏
页码:274 / 283
页数:10
相关论文
共 44 条
  • [31] Improvement in detection of pulmonary nodules: Digital image processing and computer-aided diagnosis
    MacMahon, H
    [J]. RADIOGRAPHICS, 2000, 20 (04) : 1169 - 1177
  • [32] GT OF THE CHEST - MINIMAL TUBE CURRENT REQUIRED FOR GOOD IMAGE QUALITY WITH THE LEAST RADIATION-DOSE
    MAYO, JR
    HARTMAN, TE
    LEE, KS
    PRIMACK, SL
    VEDAL, S
    MULLER, NL
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1995, 164 (03) : 603 - 607
  • [33] ACCURACY OF LUNG IMAGING IN METASTASES WITH IMPLICATIONS FOR THE ROLE OF THORACOSCOPY
    MCCORMACK, PM
    GINSBERG, KB
    BAINS, MS
    BURT, ME
    MARTINI, N
    RUSCH, VW
    GINSBERG, RJ
    LANDRENEAU, RJ
    LEWIS, RJ
    GINSBERG, RJ
    SUGARBAKER, DJ
    TEMPLETON, PA
    CERFOLIO, RJ
    TRASTEK, VF
    [J]. ANNALS OF THORACIC SURGERY, 1993, 56 (04) : 863 - 866
  • [34] Metz CE, 1999, INT CONGR SER, V1182, P543
  • [36] PULMONARY METASTATIC DISEASE - RADIOLOGIC-SURGICAL CORRELATION
    PEUCHOT, M
    LIBSHITZ, HI
    [J]. RADIOLOGY, 1987, 164 (03) : 719 - 722
  • [37] Detection of lung cancer on the chest radiograph: impact of previous films, clinical information, double reading, and dual reading
    Quekel, LGBA
    Goei, R
    Kessels, AGH
    van Engelshoven, JMA
    [J]. JOURNAL OF CLINICAL EPIDEMIOLOGY, 2001, 54 (11) : 1146 - 1150
  • [38] THURFJELL E, 1994, ACTA RADIOL, V35, P345
  • [39] BENEFIT OF INDEPENDENT DOUBLE READING IN A POPULATION-BASED MAMMOGRAPHY SCREENING-PROGRAM
    THURFJELL, EL
    LERNEVALL, KA
    TAUBE, AAS
    [J]. RADIOLOGY, 1994, 191 (01) : 241 - 244
  • [40] COMPARISON OF SINGLE READING WITH DOUBLE READING OF MAMMOGRAMS, AND CHANGE IN EFFECTIVENESS WITH EXPERIENCE
    WARREN, RML
    DUFFY, SW
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1995, 68 (813) : 958 - 962