A novel maximum power point tracking technique for solar panels using a SEPIC or Cuk converter

被引:136
作者
Chung, HSH [1 ]
Tse, KK [1 ]
Hui, SYR [1 ]
Mok, CM [1 ]
Ho, MT [1 ]
机构
[1] City Univ Hong Kong, Dept Elect & Commun Engn, Kowloon Tong, Hong Kong, Peoples R China
关键词
dc-dc power conversion; maximum-power-point-tracking; photovoltaic;
D O I
10.1109/TPEL.2003.810841
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A novel technique for efficiently extracting the maximum output power from a solar panel tinder varying meteorological conditions is presented. The methodology is based on connecting a pulse-width-modulated (PWM) dc/dc SEPIC or Cuk converter between a solar panel and a load or battery bus. The converter operates in discontinuous capacitor voltage mode whilst its input current is continuous. By modulating a small-signal sinusoidal perturbation into the duty cycle of the main switch and comparing the maximum variation in the input voltage and the voltage stress of the main switch, the maximum power point (MPP) of the panel can be located. The nominal duty cycle of the main switch in the converter is adjusted to a value, so that the input resistance of the converter is equal to the equivalent output resistance of the solar panel at the MPP. This approach ensures maximum power transfer under all conditions without using microprocessors for calculation. Detailed mathematical derivations of the, MPP tracking technique are included. The tracking capability of the proposed technique has been verified experimentally with a 10-W solar panel at different insolation (incident solar radiation) levels and under large-signal insolation level changes.
引用
收藏
页码:717 / 724
页数:8
相关论文
共 22 条
[1]  
[Anonymous], 1994, SOLAR ELECT
[2]   THE QUALITY OF LOAD-MATCHING IN A DIRECT-COUPLING PHOTOVOLTAIC SYSTEM [J].
APPLEBAUM, J .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 1987, 2 (04) :534-541
[3]   ON THE DYNAMIC OPTIMAL COUPLING OF A SOLAR-CELL ARRAY TO A LOAD AND STORAGE BATTERIES [J].
BRAUNSTEIN, A ;
ZINGER, Z .
IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1981, 100 (03) :1183-1188
[4]   Integrated photovoltaic maximum power point tracking converter [J].
Enslin, JHR ;
Wolf, MS ;
Snyman, DB ;
Swiegers, W .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 1997, 44 (06) :769-773
[5]   Controller arrangement for boost converter systems sourced from solar photovoltaic arrays or other maximum power sources [J].
Gow, JA ;
Manning, CD .
IEE PROCEEDINGS-ELECTRIC POWER APPLICATIONS, 2000, 147 (01) :15-20
[6]   MAXIMUM PHOTOVOLTAIC POWER TRACKING - AN ALGORITHM FOR RAPIDLY CHANGING ATMOSPHERIC CONDITIONS [J].
HUSSEIN, KH ;
MUTA, I ;
HOSHINO, T ;
OSAKADA, M .
IEE PROCEEDINGS-GENERATION TRANSMISSION AND DISTRIBUTION, 1995, 142 (01) :59-64
[7]   OPTIMUM LOAD-MATCHING IN DIRECT-COUPLED PHOTOVOLTAIC POWER-SYSTEMS - APPLICATION TO RESISTIVE LOADS [J].
KHOUZAM, KY .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 1990, 5 (02) :265-271
[8]  
KISLOVSKI AS, 1994, IEEE POWER ELECTRON, P1065, DOI 10.1109/PESC.1994.373812
[9]   Power-factor correction using Cuk converters in discontinuous-capacitor-voltage mode operation [J].
Lin, BT ;
Lee, YS .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 1997, 44 (05) :648-653
[10]   A Unified Analysis of PWM Converters in Discontinuous Modes [J].
Maksimovic, Dragan ;
Cuk, Slobodan .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 1991, 6 (03) :476-490