User-defined constant switching frequency current control strategy for a four-leg inverter

被引:14
作者
George, V. [1 ]
Mishra, M. K. [1 ]
机构
[1] Indian Inst Technol, Dept Elect Engn, Madras 600036, Tamil Nadu, India
关键词
SPACE-VECTOR-MODULATION; BAND CURRENT CONTROL; FILTER;
D O I
10.1049/iet-pel.2008.0057
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A novel current control strategy called user-defined constant switching frequency method for a four-leg voltage source inverter is presented. This scheme allows the user to directly set the switching frequency of all the legs. Unlike the hysteresis current control where the switching frequency is variable and the fourth leg operates at a very high frequency, the proposed method ensures a constant and reduced switching frequency for all the switches of the inverter. This is achieved by exercising an indirect control on the occurrence and duration of the uncontrollable (zero vector) states. The three legs of the inverter are operated in hysteresis current tracking mode and the switches of the fourth leg are controlled with a square pulse of fixed user-defined frequency. The above advantages supplemented with the simplicity, fast response and robustness make this an attractive scheme. The feasibility of the proposed strategy is verified through extensive simulation and experimental studies on a distribution static compensator to compensate for unbalanced and non-linear loads in a distribution power network.
引用
收藏
页码:335 / 345
页数:11
相关论文
共 25 条
[21]   Fixed-frequency space-vector-modulation control for three-phase four-leg active power filters [J].
Shen, D ;
Lehn, PW .
IEE PROCEEDINGS-ELECTRIC POWER APPLICATIONS, 2002, 149 (04) :268-274
[22]   ANALYSIS OF A PWM AC TO DC VOLTAGE SOURCE CONVERTER UNDER THE PREDICTED CURRENT CONTROL WITH A FIXED SWITCHING FREQUENCY [J].
WU, RO ;
DEWAN, SB ;
SLEMON, GR .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1991, 27 (04) :756-764
[23]  
YAO QY, 1993, IAS 93, PTS 1-3, P1122, DOI 10.1109/IAS.1993.299038
[24]   A novel hysteresis current control for active power filter with constant frequency [J].
Zeng, J ;
Yu, C ;
Qi, QR ;
Yan, Z ;
Ni, YX ;
Zhang, BL ;
Chen, SS ;
Wu, FF .
ELECTRIC POWER SYSTEMS RESEARCH, 2004, 68 (01) :75-82
[25]   Three-dimensional space vector modulation for four-leg voltage-source converters [J].
Zhang, R ;
Prasad, VH ;
Boroyevich, D ;
Lee, FC .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2002, 17 (03) :314-326