摘要
A stimulus-response method based on the application of a pH step is proposed for the detection of protein immobilized in a membrane on top of an ion-sensitive field-effect transistor (ISFET). The ISFET response to a step-wise change in pH, applied at the interface between the membrane and the surrounding solution, depends on the concentration of protein immobilized in the membrane because proton-dissociation reactions of the protein cause a delayed diffusion of protons and hydroxyl ions through the membrane. Our theoretical description shows that the delay in ISFET response is linearly related to the concentration of protein immobilized in the membrane. Experiments performed with lysozyme as a model protein show the feasibility of this detection principle. (C) 1997 Elsevier Science S.A.
引用
收藏
页码:297 / 303
页数:7
相关论文
共 10 条
[1]   A CRITICAL-EVALUATION OF DIRECT ELECTRICAL PROTEIN-DETECTION METHODS [J].
BERGVELD, P .
BIOSENSORS & BIOELECTRONICS, 1991, 6 (01) :55-72
[3]  
Crank J, 1979, MATH DIFFUSION
[4]  
EIJKEL JCT, 1995, THESIS U TWENTE ENSC
[5]  
KRUISE J, 1996, P 6 INT M CHEM SENS
[6]   MODELING OF NON-STEADY-STATE CONCENTRATION PROFILES AT ISFET-BASED COULOMETRIC SENSOR ACTUATOR SYSTEMS [J].
OLTHUIS, W ;
LUO, J ;
VANDERSCHOOT, BH ;
BERGVELD, P ;
BOS, M ;
VANDERLINDEN, WE .
ANALYTICA CHIMICA ACTA, 1990, 229 (01) :71-81
[7]   CHARACTERIZATION OF PROTEINS BY MEANS OF THEIR BUFFER CAPACITY, MEASURED WITH AN ISFET-BASED COULOMETRIC SENSOR-ACTUATOR SYSTEM [J].
OLTHUIS, W ;
LUO, J ;
BERGVELD, P .
BIOSENSORS & BIOELECTRONICS, 1994, 9 (9-10) :743-751
[8]   A NEW APPROACH TO IMMUNOFET OPERATION [J].
SCHASFOORT, RBM ;
KOOYMAN, RPH ;
BERGVELD, P ;
GREVE, J .
BIOSENSORS & BIOELECTRONICS, 1990, 5 (02) :103-124
[9]   POSSIBILITIES AND LIMITATIONS OF DIRECT DETECTION OF PROTEIN CHARGES BY MEANS OF AN IMMUNOLOGICAL FIELD-EFFECT TRANSISTOR [J].
SCHASFOORT, RBM ;
BERGVELD, P ;
KOOYMAN, RPH ;
GREVE, J .
ANALYTICA CHIMICA ACTA, 1990, 238 (02) :323-329
[10]   THE ISFET BASED HEPARIN SENSOR WITH A MONOLAYER OF PROTAMINE AS AFFINITY LIGAND [J].
VANKERKHOF, JC ;
BERGVELD, P ;
SCHASFOORT, RBM .
BIOSENSORS & BIOELECTRONICS, 1995, 10 (3-4) :269-282