Using a dedicated lung-marker system for localization of pulmonary nodules before thoracoscopic surgery

被引:38
作者
Partik, BL
Leung, AN
Müller, MR
Breitenseher, M
Eckersberger, F
Dekan, G
Helbich, TH
Metz, V
机构
[1] Stanford Univ, Med Ctr, Dept Radiol, Stanford, CA 94305 USA
[2] Univ Vienna, Dept Radiol, A-1090 Vienna, Austria
[3] Univ Vienna, Dept Cardiothorac Surg, A-1090 Vienna, Austria
[4] Univ Vienna, Dept Clin Pathol, A-1090 Vienna, Austria
关键词
D O I
10.2214/ajr.180.3.1800805
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. Our aim was to evaluate the effectiveness of a commercially available dedicated lung-marker system for localization of pulmonary nodules before video-assisted thoracoscopic surgery. SUBJECTS AND METHODS. Guidewires were positioned under CT fluoroscopy guidance in 16 patients (11 men, five women; age range, 39-79 years; mean age, 60.4 years). We measured the size of the targeted nodule, its distance to the closest pleural surface, the angle between the introducer needle and the chest wall, and the time for performance of the procedure in each patient. Note was made of any complications after guidewire placement. RESULTS. In the 16 patients, the average nodule size was 6.7 mm (range, 3-12 mm), the average distance to the pleural surface was 10.6 mm (range, 3-22 nun), and the average pleural puncture angle was 59degrees (range, 25-78degrees). The marking procedure was completed within an average of 9.5 min (range, 7-15 min). Small pneumothoraces occurred in five (31.3%) of 16 patients. In 15 (93.8%) of 16 patients, thoracoscopic resection of the targeted nodule was successful; in one patient with dyspnea (6.3%), inaccurate localization resulting in an open thoracotomy occurred because an intervening fissure was not visualized. Dislodgement of the guidewire into the pleural space occurred in one patient (6.3%). CONCLUSION. The dedicated lung-marker system is a fast and effective method for localization of pulmonary nodules before thoracoscopic resection.
引用
收藏
页码:805 / 809
页数:5
相关论文
共 25 条
[1]  
DeKerviler E, 1996, INT SURG, V81, P241
[2]  
Eckersberger F, 1997, LANGENG ARC, VSUPPL, P246
[3]  
Friedrich T, 2000, NEW ASPECTS OF HIGH TECHNOLOGY IN MEDICINE, P87
[4]   THE HOOK-WIRE TECHNIQUE FOR LOCALIZATION OF PULMONARY NODULES DURING THORACOSCOPIC RESECTION [J].
GOSSOT, D ;
MIAUX, Y ;
GUERMAZI, A ;
CELERIER, M ;
JACQUES, F .
CHEST, 1994, 105 (05) :1467-1469
[5]   Localization of pulmonary nodules for thoracoscopic resection: Experience with a system using a short hookwire and suture [J].
Kanazawa, S ;
Ando, A ;
Yasui, K ;
Mitani, M ;
Hiraki, Y ;
Shimizu, N ;
Hamanaka, D ;
Kojima, K .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 170 (02) :332-334
[6]   LOCALIZATION OF SMALL PULMONARY NODULES FOR THORACOSCOPIC RESECTION - USE OF A NEWLY DEVELOPED HOOKWIRE SYSTEM [J].
KANAZAWA, S ;
ANDO, A ;
YASUI, K ;
TANAKA, A ;
HIRAKI, Y .
CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 1995, 18 (02) :122-124
[7]   CT-guided intervention using a patient laser marker system [J].
Kloeppel, R ;
Weisse, T ;
Deckert, F ;
Wilke, W ;
Pecher, S .
EUROPEAN RADIOLOGY, 2000, 10 (06) :1010-1014
[8]  
Klöppel R, 2001, RADIOLOGE, V41, P201, DOI 10.1007/s001170050964
[9]   The solitary pulmonary nodule [J].
Leef, JL ;
Klein, JS .
RADIOLOGIC CLINICS OF NORTH AMERICA, 2002, 40 (01) :123-+
[10]   LOCALIZATION OF PULMONARY NODULES BEFORE THORACOSCOPIC SURGERY - VALUE OF PERCUTANEOUS STAINING WITH METHYLENE-BLUE [J].
LENGLINGER, FX ;
SCHWARZ, CD ;
ARTMANN, W .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 163 (02) :297-300