Quantitation of regional cerebral blood flow corrected for partial volume effect using O-15 water and PET: I. Theory, error analysis, and stereologic comparison

被引:62
作者
Iida, H
Law, I
Pakkenberg, B
Krarup-Hansen, A
Eberl, S
Holm, S
Hansen, AK
Gundersen, HJG
Thomsen, C
Svarer, C
Ring, P
Friberg, L
Paulson, OB
机构
[1] Univ Copenhagen Hosp, Rigshosp, Neurobiol Res Unit, DK-2100 Copenhagen O, Denmark
[2] Univ Copenhagen Hosp, Rigshosp, Dept Oncol, DK-2100 Copenhagen O, Denmark
[3] Univ Copenhagen Hosp, Rigshosp, Dept Clin Physiol & Nucl Med, DK-2100 Copenhagen O, Denmark
[4] Univ Copenhagen Hosp, Rigshosp, Dept Radiol, DK-2100 Copenhagen O, Denmark
[5] Res Inst Brain & Blood Vessels, Akita, Japan
[6] Copenhagen City Hosp, Bartholin Inst, Copenhagen, Denmark
[7] Hvidovre Univ Hosp, Danish Res Ctr Magnet Resonance, Copenhagen, Denmark
[8] Univ Copenhagen, Panum Inst, Dept Neurophysiol, Inst Med Physiol, Copenhagen, Denmark
[9] Royal Vet & Agr Univ, Dept Pharmacol & Pathobiol, Lab Anim Sci & Welfare, DK-1870 Frederiksberg, Denmark
[10] Univ Aarhus, Stereol Res Lab, DK-8000 Aarhus C, Denmark
[11] Royal Prince Alfred Hosp, Dept Nucl Med, Sydney, NSW, Australia
关键词
quantification; rCBF; partial volume effect; PET;
D O I
10.1097/00004647-200008000-00009
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Limited spatial resolution of positron emission tomography (PET) can cause significant underestimation in the observed regional radioactivity concentration (so-called partial volume effect or PVE) resulting in systematic errors in estimating quantitative physiologic parameters. The authors have formulated four mathematical models that describe the dynamic behavior of a freely diffusible tracer ((H2O)-O-15) in a region of interest (ROI) incorporating estimates of regional tissue flow that are independent of PVE. The current study was intended to evaluate the feasibility of these models and to establish a methodology to accurately quantify regional cerebral blood flow (CBF) corrected for PVE in cortical gray matter regions. Five monkeys were studied with PET after IV (H2O)-O-15 two times (n = 3) or three times (n = 2) in a row, Two ROIs were drawn on structural magnetic resonance imaging (MRI) scans and projected onto the PET images in which regional CBF values and the water perfusable tissue fraction for the cortical gray matter tissue thence the volume of gray matter) were estimated. After the PET study, the animals were killed and stereologic analysis was performed to assess the gray matter mass in the corresponding ROIs. Reproducibility of the estimated parameters and sensitivity to various error sources were also evaluated. All models tested in the current study yielded PVE-corrected regional CBF values (approximately 0.8 mL.min(-1).g(-1) for models with a term for gray matter tissue and 0.5 mL.min(-1).g(-1) for models with a term for a mixture of gray matter and white matter tissues). These values were greater than those obtained from ROIs tracing the gray matter cortex using conventional (H2O)-O-15 autoradiography (approximately 0.40 mL.min(-1).g(-1)). Among the four models, configurations that included two parallel tissue compartments demonstrated better results with regards to the agreement of tissue time-activity curve and the Akaike's Information Criteria. Error sensitivity analysis suggested the model that fits three parameters of the gray matter CBF, the gray matter fraction, and the white matter fraction with fixed white matter CBF as the most reliable and suitable for estimating the gray matter CBF. Reproducibility with this model was 11% for estimating the gray matter CBF. The volume of gray matter tissue can also be estimated using this model and was significantly correlated with the results from the stereologic analysis. However, values were significantly smaller compared with those measured by stereologic analysis by 40%, which can not be explained by the methodologic errors. In conclusion, the partial volume correction was essential in quantitation of regional CBF. The method presented in this article provided the PVE-corrected regional CBF in the cortical gray matter tissue. This study also suggests that further studies are required before using MRI derived anatomic information for PVE correction in PET.
引用
收藏
页码:1237 / 1251
页数:15
相关论文
共 49 条
  • [1] NEW LOOK AT STATISTICAL-MODEL IDENTIFICATION
    AKAIKE, H
    [J]. IEEE TRANSACTIONS ON AUTOMATIC CONTROL, 1974, AC19 (06) : 716 - 723
  • [2] NONINVASIVE QUANTIFICATION OF REGIONAL MYOCARDIAL BLOOD-FLOW IN CORONARY-ARTERY DISEASE WITH OXYGEN-15-LABELED CARBON-DIOXIDE INHALATION AND POSITRON EMISSION TOMOGRAPHY
    ARAUJO, LI
    LAMMERTSMA, AA
    RHODES, CG
    MCFALLS, EO
    IIDA, H
    RECHAVIA, E
    GALASSI, A
    DESILVA, R
    JONES, T
    MASERI, A
    [J]. CIRCULATION, 1991, 83 (03) : 875 - 885
  • [3] Minimum cross-entropy reconstruction of PET images using prior anatomical information
    Ardekani, BA
    Braun, M
    Hutton, BF
    Kanno, I
    Iida, H
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1996, 41 (11) : 2497 - 2517
  • [4] NONINVASIVE QUANTITATION OF MYOCARDIAL BLOOD-FLOW IN HUMAN-SUBJECTS WITH OXYGEN-15-LABELED WATER AND POSITRON EMISSION TOMOGRAPHY
    BERGMANN, SR
    HERRERO, P
    MARKHAM, J
    WEINHEIMER, CJ
    WALSH, MN
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1989, 14 (03) : 639 - 652
  • [5] EFFECT OF TISSUE HETEROGENEITY ON QUANTIFICATION IN POSITRON EMISSION TOMOGRAPHY
    BLOMQVIST, G
    LAMMERTSMA, AA
    MAZOYER, B
    WIENHARD, K
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1995, 22 (07): : 652 - 663
  • [6] CHAWLUK JB, 1987, J NUCL MED, V28, P431
  • [7] DEGRADO TR, 1994, J NUCL MED, V35, P1398
  • [8] Cerebral [O-15] water clearance in humans determined by positron emission tomography .2. Vascular responses to vibrotactile stimulation
    Fujita, H
    Meyer, E
    Reutens, DC
    Kuwabara, H
    Evans, AC
    Gjedde, A
    [J]. JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1997, 17 (01) : 73 - 79
  • [9] BAYESIAN RECONSTRUCTION OF FUNCTIONAL IMAGES USING ANATOMICAL INFORMATION AS PRIORS
    GINDI, G
    LEE, M
    RANGARAJAN, A
    ZUBAL, IG
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 1993, 12 (04) : 670 - 680
  • [10] SOME NEW, SIMPLE AND EFFICIENT STEREOLOGICAL METHODS AND THEIR USE IN PATHOLOGICAL RESEARCH AND DIAGNOSIS - REVIEW ARTICLE
    GUNDERSEN, HJG
    BENDTSEN, TF
    KORBO, L
    MARCUSSEN, N
    MOLLER, A
    NIELSEN, K
    NYENGAARD, JR
    PAKKENBERG, B
    SORENSEN, FB
    VESTERBY, A
    WEST, MJ
    [J]. APMIS, 1988, 96 (05) : 379 - 394