Polyaniline synthesis and its biosensor application

被引:130
作者
Tahir, ZM [1 ]
Alocilja, EC [1 ]
Grooms, DL [1 ]
机构
[1] Michigan State Univ, E Lansing, MI 48824 USA
关键词
polyaniline; bovine viral diarrhea virus; conductometric; immunosensor; conducting polymer; biosensor;
D O I
10.1016/j.bios.2004.08.008
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
In this study. five polyaniline compounds were synthesized using different protonic acids and incorporated into a conductometric biosensor used for bovine viral diarrhea virus detection. The biosensor was developed and evaluated by the authors for bacterial pathogen detection in previous studies. The biosensor consisted of two parts: the immunosensor and the electronic data collection system. Liquid sample moved through the immunosensor surface by capillary action. The specificity of the biosensor was based on the unique binding characteristics of the polyclonal and monoclonal antibodies immobilized on the immunosensor. Polyaniline was used in the biosensor architecture as the transducer due to its electronic and bio-molecular properties. Results showed that the biosensor was sensitive at a concentration of 101 cell culture infective dose per milliliter (CCID/ml) of BVDV antigens. The promising results on the BVDV detection demonstrated that the conductometric biosensor was interchangeable for different target molecules of detection. Further modification could be implemented to evaluate the biosensor as a rapid diagnostic device to detect other infectious disease outbreaks in livestock population. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:1690 / 1695
页数:6
相关论文
共 32 条
[1]  
ABE A, 1989, J CHEM SOC CHEM COMM, V22, P1736
[2]   Conducting polymers in microelectronics [J].
Angelopoulos, M .
IBM JOURNAL OF RESEARCH AND DEVELOPMENT, 2001, 45 (01) :57-75
[3]   THE CLINICAL MANIFESTATIONS OF BOVINE VIRAL DIARRHEA INFECTION [J].
BAKER, JC .
VETERINARY CLINICS OF NORTH AMERICA-FOOD ANIMAL PRACTICE, 1995, 11 (03) :425-&
[4]  
Barbour W. M., 1997, FOOD MICROBIOLOGY FU
[5]   A microelectrochemical switch responsive to NADH [J].
Bartlett, PN ;
Wang, JH ;
Wallace, ENK .
CHEMICAL COMMUNICATIONS, 1996, (03) :359-360
[6]  
Carbrey EA, 1971, PROC ANN MEET S ANIM, V75, P629
[7]  
CARMEN S, 1993, P 37 ANN M AM ASS VE
[8]  
DUPOET PD, 1990, ANAL CHIM ACTA, V235, P255
[9]   Application of conducting polymers to biosensors [J].
Gerard, M ;
Chaubey, A ;
Malhotra, BD .
BIOSENSORS & BIOELECTRONICS, 2002, 17 (05) :345-359
[10]   Atrazine analysis using an amperometric immunosensor based on single-chain antibody fragments and regeneration-free multi-calibrant measurement [J].
Grennan, K ;
Strachan, G ;
Porter, AJ ;
Killard, AJ ;
Smyth, MR .
ANALYTICA CHIMICA ACTA, 2003, 500 (1-2) :287-298