Basic principles of diffusion-weighted imaging

被引:583
作者
Bammer, R [1 ]
机构
[1] Stanford Univ, Lucas MRS I Ctr, Dept Radiol, Stanford, CA 94305 USA
关键词
magnetic resonance imaging; MRI; diffusion; tensor;
D O I
10.1016/S0720-048X(02)00303-0
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In diffusion-weighted MRI (DWI), image contrast is determined by the random microscopic motion of water protons. During the last years, DWI has become an important modality in the diagnostic work-up of acute ischemia in the CNS. There are also a few promising reports about the application of DWI to other regions in the human body, such as the vertebral column or the abdomen. This manuscript provides an introduction into the basics of DWI and Diffusion Tensor imaging. The potential of various MR sequences in concert with diffusion preparation are discussed with respect to acquisition speed, spatial resolution, and sensitivity to bulk physiologic motion. More advanced diffusion measurement techniques, such as high angular resolution diffusion imaging, are also addressed. (C) 2002 Elsevier Science Ireland Ltd. All rights reserved.
引用
收藏
页码:169 / 184
页数:16
相关论文
共 62 条
  • [1] Phase insensitive preparation of single-shot RARE: Application to diffusion imaging in humans
    Alsop, DC
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1997, 38 (04) : 527 - 533
  • [2] ANALYSIS AND CORRECTION OF MOTION ARTIFACTS IN-DIFFUSION WEIGHTED IMAGING
    ANDERSON, AW
    GORE, JC
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1994, 32 (03) : 379 - 387
  • [3] Atkinson D, 2000, MAGN RESON MED, V44, P101, DOI 10.1002/1522-2594(200007)44:1<101::AID-MRM15>3.0.CO
  • [4] 2-S
  • [5] Diffusion-weighted imaging with navigated interleaved echo-planar imaging and a conventional gradient system
    Bammer, P
    Stollberger, R
    Augustin, M
    Simbrunner, J
    Offenbacher, H
    Kooijman, H
    Ropele, S
    Kapeller, P
    Wach, P
    Ebner, F
    Fazekas, F
    [J]. RADIOLOGY, 1999, 211 (03) : 799 - 806
  • [6] Diffusion tensor imaging using single-shot SENSE-EPI
    Bammer, R
    Auer, M
    Keeling, SL
    Augustin, M
    Stables, LA
    Prokesch, RW
    Stollberger, R
    Moseley, ME
    Fazekas, F
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2002, 48 (01) : 128 - 136
  • [7] Diffusion-weighted imaging of the spinal cord: Interleaved echo-planar imaging is superior to fast spin-echo
    Bammer, R
    Augustin, M
    Prokesch, RW
    Stollberger, R
    Fazekas, F
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2002, 15 (04) : 364 - 373
  • [8] Diffusion imaging in multiple sclerosis
    Bammer, R
    Fazekas, F
    [J]. NEUROIMAGING CLINICS OF NORTH AMERICA, 2002, 12 (01) : 71 - +
  • [9] Improved diffusion-weighted single-shot echo-planar imaging (EPI) in stroke using Sensitivity Encoding (SENSE)
    Bammer, R
    Keeling, SL
    Augustin, M
    Pruessmann, KP
    Wolf, R
    Stollberger, R
    Hartung, HP
    Fazekas, F
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (03) : 548 - 554
  • [10] BAMMER R, 2002, 10 ANN M INT SOC MAG, P1111