Comparison of radial and Cartesian imaging techniques for MR coronary angiography

被引:5
作者
Jahnke, C
Paetsch, I
Schnackenburg, B
Gebker, R
Köhler, U
Bornstedt, A
Fleck, E
Nagel, E
机构
[1] Univ Freiburg, Dept Internal Med Cardiol, D-79106 Freiburg, Germany
[2] German Heart Inst, Dept Internal Med Cardiol, Berlin, Germany
关键词
magnetic resonance imaging; magnetic resonance coronary angiography; coronary disease; radial data acquisition;
D O I
10.1081/JCMR-200036176
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Magnetic resonance coronary angiography (MRCA) has traditionally been performed using a Cartesian k-space data acquisition scheme. Radial k-space sampling is known to be less sensitive to motion artifacts. Thus, potential improvements may be achieved with radial k-space data acquisition using steady state free precession (SSFP) techniques. We directly compared SSFP three-dimensional (3D)-MRCA using radial and Cartesian data acquisition. Methods: Forty-four consecutive patients with suspected coronary artery disease underwent free-breathing, navigator-corrected MRCA of the left or right coronary artery using SSFP (TR/TE/flip angle: 4.5 ms/2.3 ms/90degrees) with radial and again with Cartesian k-space filling. Quantitative MRCA was performed with a dedicated multiplanar reformatting software to determine: visual score for image quality (low=1, high=4), vessel sharpness, visible vessel length, number of visible side branches, and average vessel diameter. Diagnostic accuracy for detection of greater than or equal to50% coronary artery stenosis was calculated in comparison to invasive X-ray angiography. Results: Radial data acquisition resulted in a significant (p<0.01) increase in vessel sharpness (55.6 +/- 7.2% vs. 45.9 +/- 7.0%) but a decrease in average vessel diameter (2.6 +/- 0.5 mm vs. 3.0 +/- 0.4 mm), number of visible side branches (2.1 +/- 1.1 vs. 3.0 +/- 1.7) and number of assessable coronary artery segments (66% vs. 73%) compared to Cartesian approach. There was no significant difference regarding the diagnostic accuracy (80.8% vs. 83.9%), the visual score (2.6 +/- 0.9 vs. 3.0 +/- 0.9) and the visible vessel length (92.1 +/- 36.0 mm vs. 99.9 +/- 32.4 mm). Conclusions: MRCA with radial k-space sampling appears to be on a par with Cartesian approach with respect to the diagnostic performance in an unselected patient population. Nevertheless, with current implementations, radial sampling is inferior to Cartesian sampling regarding the visualization of side branches despite better vessel sharpness.
引用
收藏
页码:865 / 875
页数:11
相关论文
共 38 条
[1]   CORONARY-ARTERY IMAGING AT 0.5 T USING SEGMENTED 3D ECHO-PLANAR IMAGING [J].
BORNERT, P ;
JENSEN, D .
MAGNETIC RESONANCE IN MEDICINE, 1995, 34 (06) :779-785
[2]  
Börnert P, 2001, MAGNET RESON MED, V45, P172, DOI 10.1002/1522-2594(200101)45:1<172::AID-MRM1024>3.0.CO
[3]  
2-L
[4]  
Botnar RM, 1999, JMRI-J MAGN RESON IM, V10, P821, DOI 10.1002/(SICI)1522-2586(199911)10:5<821::AID-JMRI29>3.0.CO
[5]  
2-7
[6]   Improved coronary artery definition with T2-weighted, free-breathing, three-dimensional coronary MRA [J].
Botnar, RM ;
Stuber, M ;
Danias, PG ;
Kissinger, KV ;
Manning, WJ .
CIRCULATION, 1999, 99 (24) :3139-3148
[7]   CORONARY ANGIOGRAPHY WITH MAGNETIZATION-PREPARED T-2 CONTRAST [J].
BRITTAIN, JH ;
HU, BS ;
WRIGHT, GA ;
MEYER, CH ;
MACOVSKI, A ;
NISHIMURA, DG .
MAGNETIC RESONANCE IN MEDICINE, 1995, 33 (05) :689-696
[8]   Prospective navigator correction of image position for coronary MR angiography [J].
Danias, PG ;
McConnell, MV ;
Khasgiwala, VC ;
Chuang, ML ;
Edelman, RR ;
Manning, WJ .
RADIOLOGY, 1997, 203 (03) :733-736
[9]   3D magnetization-prepared true-FISP: A new technique for imaging coronary arteries [J].
Deshpande, VS ;
Shea, SM ;
Laub, G ;
Simonetti, OP ;
Finn, JP ;
Li, DB .
MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (03) :494-502
[10]   Remember true FISP? A high SNR, near 1-second imaging method for T2-like contrast in interventional MRI at .2 T [J].
Duerk, JL ;
Lewin, JS ;
Wendt, M ;
Petersilge, C .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (01) :203-208