Three-dimensional position sensing and field shaping in orthogonal-strip germanium gamma-ray detectors

被引:92
作者
Amman, M [1 ]
Luke, PN [1 ]
机构
[1] Univ Calif Berkeley, Ernest Orlando Lawrence Berkeley Natl Lab, Berkeley, CA 94720 USA
关键词
gamma-ray imaging; gamma-ray spectroscopy; germanium detector; orthogonal strip; position sensing; field shaping;
D O I
10.1016/S0168-9002(00)00351-X
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We have fabricated a prototype orthogonal-strip germanium detector for gamma-ray imaging studies. With this detector we demonstrate that a gamma-ray interaction event in the detector can be located in three dimensions. In particular, we determine the interaction depth from the difference in time in the arrival of the holes at an electrode on one side of the detector and the arrival of the electrons at an electrode on the opposing detector surface. This depth of interaction sensing should lead to improved image resolution. A separate issue with such a detector is the loss of energy resolution and efficiency resulting from incomplete charge collection for interaction events taking place in the gap regions between the detector electrodes. We also demonstrate with our prototype detector that this problem can be substantially reduced by using field-shaping electrodes. A bias applied between the charge-sensing electrodes and the held-shaping electrodes improves the charge collection to the charge-sensing electrodes and consequently the detector performance. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:155 / 166
页数:12
相关论文
共 23 条
[1]   CHARGE-TRANSPORT IN ARRAYS OF SEMICONDUCTOR GAMMA-RAY DETECTORS [J].
BARRETT, HH ;
ESKIN, JD ;
BARBER, HB .
PHYSICAL REVIEW LETTERS, 1995, 75 (01) :156-159
[2]  
Berger M.J., 1998, NIST Standard Reference Database (XGAM), V8, P87
[3]  
DETKO JF, 1973, MED RADIOISOTOPE SCI, P241
[4]   PHOTOMASK TECHNIQUE FOR FABRICATING HIGH-PURITY GERMANIUM STRIP DETECTORS [J].
GUTKNECHT, D .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1990, 288 (01) :13-18
[5]   PERFORMANCE OF POSITION-SENSITIVE GERMANIUM DETECTORS IN NUCLEAR-REACTION EXPERIMENTS [J].
HAMACHER, A ;
MACHNER, H ;
NOLTE, M ;
PALARCZYK, M ;
PROTIC, D ;
RIEPE, G .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1990, 295 (1-2) :128-132
[6]   AMORPHOUS-GERMANIUM AS AN ELECTRON OR HOLE BLOCKING CONTACT ON HIGH-PURITY GERMANIUM DETECTORS [J].
HANSEN, WL ;
HALLER, EE .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1977, 24 (01) :61-63
[7]   2-DETECTOR, 512-ELEMENT HIGH-PURITY GERMANIUM CAMERA PROTOTYPE [J].
KAUFMAN, L ;
LORENZ, V ;
HOSIER, K ;
HOENNINGER, J ;
HATTNER, RS ;
OKERLUND, M ;
PRICE, DC ;
SHAMES, DM ;
SWANN, SJ ;
EWINS, JH ;
ARMANTROUT, GA ;
CAMP, DC ;
LEE, K .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1978, 25 (01) :189-195
[8]   Charge spreading and position sensitivity in a segmented planar germanium detector [J].
Kroeger, RA ;
Gehrels, N ;
Johnson, WN ;
Kurfess, JD ;
Phlips, BP ;
Tueller, J .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 422 (1-3) :206-210
[10]   A 140-ELEMENT GE DETECTOR FABRICATED WITH AMORPHOUS-GE BLOCKING CONTACTS [J].
LUKE, PN ;
PEHL, RH ;
DILMANIAN, FA .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1994, 41 (04) :976-978