Electrochemical Sensor Based on Ionic Liquid Crystal Modified Carbon Paste Electrode in Presence of Surface Active Agents for Enoxacin Antibacterial Drug

被引:28
作者
Atta, Nada F. [1 ]
Galal, Ahmed [1 ]
Azab, Shereen M. [2 ]
Ibrahim, Asmaa H. [2 ]
机构
[1] Cairo Univ, Fac Sci, Dept Chem, Giza 12013, Egypt
[2] Natl Org Drug Control & Res, Giza, Egypt
关键词
VOLTAMMETRIC DETERMINATION; HUMAN SERUM; FLUOROQUINOLONES; ELECTROPHORESIS; HYDROQUINONE; NANOTUBES; BEHAVIOR; GUANINE; URINE; ACID;
D O I
10.1149/2.0251501jes
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
A sensitive electrochemical sensor based on carbon paste and inclusion of ionic liquid crystal [(1-Butyl-1-methylpiperidinium hexafluorophosphate)] in presence of sodium dodecyl sulfate (ILCMCPE.....SDS) for the electrochemical determination of Enoxacin (EN) was prepared. Different ionic liquids were used and compared, namely (1-n-Hexyl-3-methyl imidazolium tetrafluoroborate) (ILMCPE1.....SDS) and (1-Butyl-4-methyl pyridinium tetrafluoroborate) (ILMCPE2.....SDS). The studied ionic liquids mimic cell membranes for their interaction with drug intake through cell membranes. We found that ILCMCPE.....SDS exhibited good electrochemical performances with higher conductivity and lower electron transfer resistance due to the combining effect of high ion conductivity, sensitivity, fast electron transfer, stability and antifouling ability of the ionic liquid crystal. SDS enhanced the preconcentration/accumulation of EN species in the ionic form at the surface. Excellent performance of ILCMCPE.....SDS for the determination of EN in the linear dynamic range of 6.67x10(-7) to 2.22x10(-5) mol L-1 with a correlation coefficient 0.9998 and LOD 3.28x10(-9) mol L-1. Simultaneous determination of binary mixtures dopamine/enoxacin and epinephrine/enoxacin was demonstrated with good peak potentials separations. This method was successfully applied for direct determination of EN in human urine samples with good recovery results. The ILCMCPE.....SDS showed also high reproducibility selectivity and anti -interference ability. (C) 2014 The Electrochemical Society. All rights reserved.
引用
收藏
页码:B9 / B15
页数:7
相关论文
共 50 条
[21]   An ionic liquid-type carbon paste polyoxometalate-modified electrode and its properties [J].
Liu, HT ;
He, P ;
Li, ZY ;
Sun, CY ;
Shi, LH ;
Liu, Y ;
Zhu, GY ;
Li, JH .
ELECTROCHEMISTRY COMMUNICATIONS, 2005, 7 (12) :1357-1363
[22]   Electrochemical behavior and electrochemical determination of carbamazepine at an ionic liquid modified carbon paste electrode in the presence of sodium dodecyl sulfate [J].
Liu, Li-Hong ;
Duan, Cheng-Qian ;
Gao, Zuo-Ning .
JOURNAL OF THE SERBIAN CHEMICAL SOCIETY, 2012, 77 (04) :483-496
[23]   Electrochemical behavior of hydroquinone at multi-walled carbon nanotubes and ionic liquid composite film modified electrode [J].
Liu, Xiuhui ;
Ding, Zhen ;
He, Yuehua ;
Xue, Zhonghua ;
Zhao, Xueping ;
Lu, Xiaoquan .
COLLOIDS AND SURFACES B-BIOINTERFACES, 2010, 79 (01) :27-32
[24]   Flow-injection electrogenerated chemiluminescence determination of fluoroquinolones based on its sensitizing effect [J].
Ma, HY ;
Zheng, XW ;
Zhang, ZJ .
LUMINESCENCE, 2005, 20 (4-5) :303-306
[25]   High-performance carbon composite electrode based on an ionic liquid as a binder [J].
Maleki, Norouz ;
Safavi, Afsaneh ;
Tajabadi, Fariba .
ANALYTICAL CHEMISTRY, 2006, 78 (11) :3820-3826
[26]   Discotic liquid crystals stabilized by interionic interactions: imidazolium ion-anchored paraffinic triphenylene [J].
Motoyanagi, J ;
Fukushima, T ;
Aida, T .
CHEMICAL COMMUNICATIONS, 2005, (01) :101-103
[27]   Sensitive and stable amperometric measurements at ionic liquid-carbon paste microelectrodes [J].
Musameh, Mustafa ;
Wang, Joseph .
ANALYTICA CHIMICA ACTA, 2008, 606 (01) :45-49
[28]   A review on electrodes modified with ionic liquids [J].
Opallo, Marcin ;
Lesniewski, Adam .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2011, 656 (1-2) :2-16
[29]   Analytical applications of room-temperature ionic liquids: A review of recent efforts [J].
Pandey, S .
ANALYTICA CHIMICA ACTA, 2006, 556 (01) :38-45
[30]   An ionic liquid coating for determination of sildenafil and UK-103,320 in human serum by capillary zone electrophoresis-ion trap mass spectrometry [J].
Qin, WD ;
Li, SFY .
ELECTROPHORESIS, 2002, 23 (24) :4110-4116