A high flexion total knee arthroplasty design replicates healthy knee motion

被引:69
作者
Argenson, JNA
Komistek, RD
Mahfouz, M
Walker, SA
Aubaniac, JM
Dennis, DA
机构
[1] Univ Aix Marseille, Hop St Marguerite, Marseille, France
[2] Univ Tennessee, Knoxville, TN USA
[3] Oak Ridge Natl Lab, Oak Ridge, TN USA
关键词
D O I
10.1097/01.blo.0000148948.79128.76
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Deep flexion affects both femorotibial contact pattern and the patellofemoral articulation. The purpose of this study was to compare the patellofemoral motion of nonimplanted and implanted knees and to analyze femorotibial kinematics after total knee replacement designed for deep flexion. Three-dimensional patellofemoral kinematics were evaluated during a deep knee bend using fluoroscopy for five control patients with a healthy knee, five patients with an anterior-cruciate-ligament-deficient knee, and 20 patients who had a high flexion total knee arthroplasty. Less translation of patellofemoral contact position was seen in patients who had knee replacements than in patients with healthy knees, but the average motion and the patella tilt angles were similar to the healthy knees. On average, patients who had a total knee arthroplasty had 4.9degrees normal axial rotation, and all patients had at least -4.4 mm of posterior femoral roll-back. The average weightbearing range of motion of the patients in the total knee arthroplasty group was 125degrees. In this study, patients implanted with a high-flexion knee replacement design had kinematic patterns that were similar to the healthy knee. It can be hypothesized that forces acting on the patella were not substantially increased for patients who had a total knee arthroplasty compared with the control patients.
引用
收藏
页码:174 / 179
页数:6
相关论文
共 22 条
[1]  
ARGENSON JN, IN PRESS J BIOMECH
[2]   In vivo three-dimensional patellar tracking on the femur [J].
Asano, T ;
Akagi, M ;
Koike, K ;
Nakamura, T .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2003, (413) :222-232
[3]   Knee motions during maximum flexion in fixed and mobile-bearing arthroplasties [J].
Banks, S ;
Bellemans, J ;
Nozaki, H ;
Whiteside, LA ;
Harman, M ;
Hodge, WA .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2003, (410) :131-138
[4]   In vivo kinematics of cruciate-retaining and -substituting knee arthroplasties [J].
Banks, SA ;
Markovich, GD ;
Hodge, WA .
JOURNAL OF ARTHROPLASTY, 1997, 12 (03) :297-304
[5]   Fluoroscopic analysis of the kinematics of deep flexion in total knee arthroplasty - Influence of posterior condylar offset [J].
Bellemans, J ;
Banks, S ;
Victor, J ;
Vandenneucker, H ;
Moemans, A .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2002, 84B :50-53
[6]   In vivo three-dimensional determination of kinematics for subjects with a normal knee or a unicompartmental or total knee replacement [J].
Dennis, D ;
Komistek, R ;
Scuderi, G ;
Argenson, JN ;
Insall, J ;
Mahfouz, M ;
Aubaniac, JM ;
Haas, B .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2001, 83A :104-115
[7]  
Dennis DA, 1998, CLIN ORTHOP RELAT R, P47
[8]   Femoral condylar lift-off in vivo in total knee arthroplasty [J].
Dennis, DA ;
Komistek, RD ;
Walker, SA ;
Cheal, EJ ;
Stiehl, JB .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2001, 83B (01) :33-39
[9]   In vivo fluoroscopic analysis of fixed-bearing total knee replacements [J].
Dennis, DA ;
Komistek, RD ;
Mahfouz, MR .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2003, (410) :114-130
[10]  
DENNIS DA, 2004, CLIN ORTHOP RELAT R, V428, pR30