Combination of ionic liquid-based dispersive liquid-liquid micro-extraction with stopped-flow spectrofluorometry for the pre-concentration and determination of aluminum in natural waters, fruit juice and food samples

被引:80
作者
Abdolmohammad-Zadeh, H. [1 ]
Sadeghi, G. H. [1 ]
机构
[1] Azarbaijan Univ Tarbiat Moallem, Fac Sci, Dept Chem, Tabriz, Iran
关键词
Aluminum; Ionic liquid; Dispersive liquid-liquid micro-extraction; Stopped-flow spectrofluorometry; ATOMIC-ABSORPTION-SPECTROMETRY; CLOUD POINT PRECONCENTRATION; MICROEXTRACTION TECHNIQUE; PARENTERAL SOLUTIONS; SOLVENT; HEXAFLUOROPHOSPHATE; SEPARATION; SPECIATION; CADMIUM; MERCURY;
D O I
10.1016/j.talanta.2010.01.012
中图分类号
O65 [分析化学];
学科分类号
070302 [分析化学];
摘要
In this research, we combined ionic liquid-based dispersive liquid-liquid micro-extraction (IL-based DLLME) with stopped-flow spectrofluorometry (SFS) to evaluate the concentration of aluminum in different real samples at trace level. 1-Hexylpyridinium hexafluorophosphate [Hpy][PF6] ionic liquid and 8-hydroxyquinoline (oxine), which forms a highly fluorescent complex with Al3+, were chosen as the extraction solvent and chelating agent, respectively. The hydrophobic Al-oxine complex was extracted into the [Hpy][PF6] and separated from the aqueous phase. Then, the concentration of the enriched aluminum in the sediment phase was determined by SFS. Some effective parameters that influence the SFS signals and the micro-extraction efficiency, such as the suction and sending time, the concentration of the chelating agent, pH, the amount of the ionic liquid, the type of disperser solvent and diluting agent, ionic strength, extraction time, equilibration temperature and centrifugation time were investigated and optimized. In the optimum experimental conditions, the limit of detection (3 s) and enrichment factor were 0.05 mu g L-1 and 100, respectively. The relative standard deviation (RSD) for six replicate determinations of 6 mu g L-1 Al was 1.7%. The calibration graph using the pre-concentration system was linear in the range of 0.06-15 mu g L-1 with a correlation coefficient of 0.9989. The developed method was validated by the analysis of certified reference materials and applied successfully to the determination of aluminum in several water, fruit juice and food samples. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:778 / 785
页数:8
相关论文
共 38 条
[1]
A novel microextraction technique based on 1-hexylpyridinium hexafluorophosphate ionic liquid for the preconcentration of zinc in water and milk samples [J].
Abdolmohammad-Zadeh, H. ;
Sadeghi, G. H. .
ANALYTICA CHIMICA ACTA, 2009, 649 (02) :211-217
[2]
Hollow fiber based-liquid phase microextraction using ionic liquid solvent for preconcentration of lead and nickel from environmental and biological samples prior to determination by electrothermal atomic absorption spectrometry [J].
Abulhassani, Jafar ;
Manzoori, Jamshid L. ;
Amjadi, Mohammad .
JOURNAL OF HAZARDOUS MATERIALS, 2010, 176 (1-3) :481-486
[3]
Flow-injection solvent extraction with and without phase separation - Fluorimetric determination of aluminium in water [J].
Alonso, A ;
Almendral, MJ ;
Porras, MJ ;
Curto, Y ;
de Maria, CG .
ANALYTICA CHIMICA ACTA, 2001, 447 (1-2) :211-217
[4]
In situ solvent formation microextraction based on ionic liquids: A novel sample preparation technique for determination of inorganic species in saline solutions [J].
Baghdadi, Majid ;
Shemirani, Farzaneh .
ANALYTICA CHIMICA ACTA, 2009, 634 (02) :186-191
[5]
Cold-induced aggregation microextraction: A novel sample preparation technique based on ionic liquids [J].
Baghdadi, Majid ;
Shemirani, Farzaneh .
ANALYTICA CHIMICA ACTA, 2008, 613 (01) :56-63
[6]
Ionic liquids in separation techniques [J].
Berthod, A. ;
Ruiz-Angel, Mt ;
Carda-Broch, S. .
JOURNAL OF CHROMATOGRAPHY A, 2008, 1184 (1-2) :6-18
[7]
BERTON P, 2009, J HAZARD MATER, DOI DOI 10.1016/JJHAZMAT.2009.11.094
[8]
Room temperature ionic liquid-based microextraction for vanadium species separation and determination in water samples by electrothermal atomic absorption spectrometry [J].
Berton, Paula ;
Martinis, Estefania M. ;
Martinezc, Luis D. ;
Wuilloud, Rodolfo G. .
ANALYTICA CHIMICA ACTA, 2009, 640 (1-2) :40-46
[9]
Cold-induced aggregation microextraction based on ionic liquids and fiber optic-linear array detection spectrophotometry of cobalt in water samples [J].
Gharehbaghi, Maysam ;
Shemirani, Farzaneh ;
Farahani, Malihe Davudabadi .
JOURNAL OF HAZARDOUS MATERIALS, 2009, 165 (1-3) :1049-1055
[10]
Use of 1-alkyl-3-methylimidazolium hexafluorophosphate room temperature ionic liquids as chelate extraction solvent with 4,4,4-trifluoro-1-(2-thienyl)-1,3-butanedione [J].
Hirayama, N ;
Deguchi, M ;
Kawasumi, H ;
Honjo, T .
TALANTA, 2005, 65 (01) :255-260