The role of scintimammography with 99mTc-sestamibi as a complementary diagnostic technique in the detection of breast cancer

被引:12
作者
Danielsson, R
Reihnér, E
Grabowska, A
Boné, B
机构
[1] Huddinge Univ Hosp, Dept Diagnost Radiol, S-14186 Huddinge, Sweden
[2] Huddinge Univ Hosp, Karolinska Inst, Dept Surg, S-14186 Huddinge, Sweden
关键词
breast carcinoma; triple diagnosis; scintimammography; diagnostic accuracy;
D O I
10.1080/028418500127345659
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To prospectively determine the clinical Value of scintimammography (Sc) with Tc-99m-sestamibi as a complementary method to triple diagnosis (TD) in detecting malignant disease of the breast. Material and Methods. Ninety-six patients with 119 clinically or mammographically detected breast lesions underwent TD procedures, including clinical examination, mammography and fine-needle aspiration cytology. Prone planar Sc with Tc-99m-sestamibi was performed in all 96 patients. Five groups were defined for diagnosis: 1=normal; 2=benign; 3=probably benign; 4=highly suspect of malignancy; and 5=malignant. All lesions were histopathologically examined. The results of each method pet se and the combination of TD with Sc (TD+Sc) were analyzed. Results: Histopathology of the 119 surgically excised breast lesions found 83 malignant and 36 benign lesions. TD missed 6 of 83 carcinomas, resulting in a sensitivity of 92.7%. Sc alone showed sensitivity of 85.5%. The combination TD+Sc missed 1 of 83 carcinomas, and thus had a sensitivity of 98.7%. In mammographically dense breasts both TD and Sc detected 16 of 18 carcinomas, while the combination TD+Sc led to detection of all 18 carcinomas. Conclusion. Adding Sc to TD increases the sensitivity for detection of breast carcinomas. Sc with Tc-99m-sestamibi is recommended as a complimentary method to TD in selected cases such as mammographically dense breasts.
引用
收藏
页码:441 / 445
页数:5
相关论文
共 21 条
[1]  
*AM COLL RAD ACR, 1995, AM COLL RAD
[2]  
Bombardieri E, 1997, EUR J NUCL MED, V24, P809
[3]  
BONE B, 1997, THESIS STOCKHOLM
[4]  
BUSCOMBE J, 1998, SCINTIMAMMOGRAPHY GU
[5]   Comparison of accuracy of scintimammography and X-ray mammography in the diagnosis of primary breast cancer in patients selected for surgical biopsy [J].
Cwikla, JB ;
Buscombe, JR ;
Kelleher, SM ;
Parbhoo, SP ;
Thakrar, DS ;
Hinton, J ;
Deery, AR ;
Crow, J ;
Hilson, AJW .
CLINICAL RADIOLOGY, 1998, 53 (04) :274-280
[6]   Sensitivity and specificity of planar scintimammography with 99mTc-sestamibi [J].
Danielsson, R ;
Boné, B ;
Gad, A ;
Sylvan, M ;
Aspelin, P .
ACTA RADIOLOGICA, 1999, 40 (04) :394-399
[7]  
DONAGAN WL, 1995, CANC BREAST
[8]  
HERMANSEN C, 1987, CANCER, V60, P1866, DOI 10.1002/1097-0142(19871015)60:8<1866::AID-CNCR2820600832>3.0.CO
[9]  
2-Z
[10]  
Khalkhali I, 1997, Q J Nucl Med, V41, P231