Comparison of accuracy of scintimammography and X-ray mammography in the diagnosis of primary breast cancer in patients selected for surgical biopsy

被引:20
作者
Cwikla, JB
Buscombe, JR
Kelleher, SM
Parbhoo, SP
Thakrar, DS
Hinton, J
Deery, AR
Crow, J
Hilson, AJW
机构
[1] Royal Free Hosp, Dept Nucl Med, London NW3 2QG, England
[2] Royal Free Hosp, Dept Breast Surg, London NW3 2QG, England
[3] Royal Free Hosp, Dept Radiol, London NW3 2QG, England
[4] Royal Free Hosp, Dept Pathol, London NW3 2QG, England
[5] Sch Med, London, England
关键词
D O I
10.1016/S0009-9260(98)80126-8
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Mammography, whilst remaining the fia st line imaging investigation of Suspected primary breast cancer, can be difficult to interpret ire patients with fibrous or dense breasts, Radionuclide imaging of the breast (scintimammography) has been suggested as an additional test. The aim of this study was to perform prospectively a comparison of the two techniques in a population with suspected breast cancer. Seventy such patients, mean age 54 years (range 57 years, 28-85) with 74 suspicious breast lesions were studied, They were imaged 5-10 min after intravenous injection of 740 MBq of Tc-99m sestamibi. Prone lateral and anterior supine views with and without markers were performed, all patients had histological confirmation of the nature of the breast lesions by limited incisional biopsy or definitive nide local excision, or cytological confirmation on fine needle aspiration. All patients had X-ray mammography. There were 53 malignant breast tumours and 21 benign lesions, Scintimammography correctly diagnosed 47 breast cancers, and yielded true-negative results in 12 benign breast lesions, There mere six cases of false-negative results and nine false-positive results, Four scans were reported as equivocal, The sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were 89%, 52%, 84% and 67%, respectively. X-ray mammography diagnosed correctly 37 malignant tumours, and in 12 benign lesions the results were true negatives. Ten studies were reported as equivocal. The sensitivity, specificity, PPV and NPV were 70%, 57%, 80% and 43%, respectively. The accuracy of Tc-99m sestamibi scintimammography was better than X-ray mammography though this was not significant (McNemar's test). Fewer equivocal results were obtained with scintimammography. Scintimammography may therefore hare a role in the diagnosis of primary breast cancer when X-ray mammography is equivocal or unhelpful.
引用
收藏
页码:274 / 280
页数:7
相关论文
共 20 条
[1]   CLINICAL-EXPERIENCE WITH TC-99M MIBI IMAGING IN PATIENTS WITH MALIGNANT-TUMORS - PRELIMINARY-RESULTS AND COMPARISON WITH TL-201 [J].
AKTOLUN, C ;
BAYHAN, H ;
KIR, M .
CLINICAL NUCLEAR MEDICINE, 1992, 17 (03) :171-176
[2]  
ANDERSON TJ, 1994, OXFORD TXB PATHOLOGY, P1643
[3]   EVALUATION OF PALPABLE BREAST MASSES WITH TC-99M-MIBI - A COMPARATIVE-STUDY WITH MAMMOGRAPHY AND ULTRASONOGRAPHY [J].
BURAK, Z ;
ARGON, M ;
MEMIS, A ;
ERDEM, S ;
BALKAN, Z ;
DUMAN, Y ;
USTUN, EE ;
ERHAN, Y ;
OZKILIC, H .
NUCLEAR MEDICINE COMMUNICATIONS, 1994, 15 (08) :604-612
[4]  
Buscombe JR, 1997, ANTICANCER RES, V17, P1693
[5]  
CANER B, 1991, J NUCL MED, V32, P1977
[6]  
Diggles L., 1994, Journal of Nuclear Medicine Technology, V22, P165
[7]  
HARRIS JR, 1993, CANC PRINCIPLES PRAC
[8]   UPTAKE AND KINETICS OF TC-99M HEXAKIS 2-METHOXY ISOBUTYL ISONITRILE IN BENIGN AND MALIGNANT LESIONS IN THE LUNGS [J].
HASSAN, IM ;
SAHWEIL, A ;
CONSTANTINIDES, C ;
MAHMOUD, A ;
NAIR, M ;
OMAR, YT ;
ABDELDAYEM, HM .
CLINICAL NUCLEAR MEDICINE, 1989, 14 (05) :333-340
[9]  
KAO CH, 1994, EUR J NUCL MED, V21, P432
[10]  
KHALKHALI I, 1994, J AM COLL SURGEONS, V178, P491