1.5 T: spectroscopy-supported brain biopsy

被引:18
作者
Hall, WA
Truwit, CL
机构
[1] Univ Minnesota, Sch Med, Dept Neurosurg, Minneapolis, MN 55455 USA
[2] Univ Minnesota, Sch Med, Dept Radiat Oncol, Minneapolis, MN 55455 USA
[3] Univ Minnesota, Sch Med, Dept Radiol, Minneapolis, MN 55455 USA
[4] Univ Minnesota, Sch Med, Dept Pediat, Minneapolis, MN 55455 USA
[5] Univ Minnesota, Sch Med, Dept Neurol, Minneapolis, MN 55455 USA
关键词
D O I
10.1016/j.nec.2004.07.002
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
The technique for performing brain biopsy has evolved significantly over the last three decades. Intraoperative MRI guidance has enhanced the diagnostic rate for brain biopsy by now allowing neurosurgeons to compensate for brain shift while performing the procedure in near-real time. The development of a trajectory guide enables the neurosurgeon to determine a safe and accurate path for intraoperative MRI-guided brain biopsy and to secure the position of the needle within the target tissue. Magnetic resonance spectroscopy (MRS) has been used to help distinguish recurrent brain tumor from the effect of previous treatments by measuring specific metabolites within the area of concern. Combining the use of a trajectory guide with MRS should enhance the diagnostic yield for MRI-guided brain biopsy.
引用
收藏
页码:165 / +
页数:9
相关论文
共 23 条
  • [1] A new artifact-free device for frameless, magnetic resonance imaging-guided stereotactic procedures
    Bernays, RL
    Kollias, SS
    Khan, N
    Romanowski, B
    Yonekawa, Y
    [J]. NEUROSURGERY, 2000, 46 (01) : 112 - 116
  • [2] Brain tumor surgery with the Toronto open magnetic resonance imaging system: Preliminary results for 36 patients and analysis of advantages, disadvantages, and future prospects
    Bernstein, M
    Al-Anazi, AR
    Kucharczyk, W
    Manninen, P
    Bronskill, M
    Henkelman, M
    [J]. NEUROSURGERY, 2000, 46 (04) : 900 - 907
  • [3] Development and implementation of intraoperative magnetic resonance imaging and its neurosurgical applications
    Black, PM
    Moriarty, T
    Alexander, E
    Stieg, P
    Woodard, EJ
    Gleason, PL
    Martin, CH
    Kikinis, R
    Schwartz, RB
    Jolesz, FA
    [J]. NEUROSURGERY, 1997, 41 (04) : 831 - 842
  • [4] Safety, efficacy, and functionality of high-field strength interventional magnetic resonance imaging for neurosurgery
    Hall, WA
    Liu, HY
    Martin, AJ
    Pozza, CH
    Maxwell, RE
    Truwit, CL
    [J]. NEUROSURGERY, 2000, 46 (03) : 632 - 641
  • [5] Hall WA, 2003, ACT NEUR S, V85, P29
  • [6] Hall WA, 1998, CANCER, V82, P1749, DOI 10.1002/(SICI)1097-0142(19980501)82:9<1756::AID-CNCR23>3.0.CO
  • [7] 2-2
  • [8] Brain biopsy using high-field strength interventional magnetic resonance imaging
    Hall, WA
    Martin, AJ
    Liu, HY
    Nussbaum, ES
    Maxwell, RE
    Truwit, CL
    [J]. NEUROSURGERY, 1999, 44 (04) : 807 - 813
  • [9] Navigus trajectory guide
    Hall, WA
    Liu, HY
    Truwit, CL
    [J]. NEUROSURGERY, 2000, 46 (02) : 502 - 504
  • [10] Hall WA, 2001, NEUROIMAG CLIN N AM, V11, P705