Calculation of HVdc converter noncharacteristic harmonics using digital time-domain simulation method

被引:1
作者
Sarshar, A [1 ]
Iravani, MR [1 ]
Li, J [1 ]
机构
[1] UNIV TORONTO,DEPT ELECT & COMP ENGN,TORONTO,ON M5S 1A4,CANADA
关键词
noncharacteristic harmonics; triplen harmonics; second harmonic instability; HVDC-AC interaction; transformer half-cycle saturation; GIC;
D O I
10.1109/61.484033
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 [电气工程]; 0809 [电子科学与技术];
摘要
In this paper, noncharacteristic harmonics of an HVdc converter station are calculated based on the use of digital time-domain simulation methods. An enhanced version of the Electromagnetic Transients Program (EMTP) is used for the studies. The noncharacteristic harmonics of interest are (1) the dc side triplen harmonics, and (2) the ac side second harmonic. Impacts of loading conditions, neutral filter, and converter firing angle on the de side triplen harmonics are discussed. Effects of ac side network parameters, static VAR compensator (SVC), transformer half-cycle saturation, and Geomagnetically Induced Current (GIC) on the ac side second harmonic instability are also presented. This paper concludes that the digital time-domain simulation method provides significant flexibility for accurate prediction of (1) generation mechanism, and (2) adverse impacts of HVdc noncharacteristic harmonics.
引用
收藏
页码:335 / 344
页数:10
相关论文
共 20 条
[1]
[Anonymous], 1971, DIRECT CURRENT TRANS
[2]
ANALYSIS OF DC HARMONICS USING THE 3 PULSE MODEL FOR THE INTERMOUNTAIN POWER PROJECT HVDC TRANSMISSION [J].
DICKMANDER, DL ;
PETERSON, KJ .
IEEE TRANSACTIONS ON POWER DELIVERY, 1989, 4 (02) :1195-1204
[3]
ALTERNATIVES FOR BLOCKING DIRECT-CURRENT IN AC SYSTEM NEUTRALS AT THE RADISSON LG2 COMPLEX [J].
EITZMANN, MA ;
WALLING, RA ;
HUYNH, H ;
GRANGER, M ;
SUBLICH, M ;
KHAN, A ;
THANAWALA, HL ;
DUTIL, A ;
KAPPENMAN, JG .
IEEE TRANSACTIONS ON POWER DELIVERY, 1992, 7 (03) :1328-1337
[4]
ELMARSAFAWAY M, 1983, IEE P, V135, P28
[5]
MEASUREMENT OF HARMONIC CURRENTS AND EVALUATION OF THE DC FILTER PERFORMANCE OF THE NEW-ENGLAND HYDRO QUEBEC PHASE-I HVDC PROJECT [J].
GARRITY, TF ;
HASSAN, ID ;
ADAMSON, KA ;
DONAHUE, JA .
IEEE TRANSACTIONS ON POWER DELIVERY, 1989, 4 (01) :779-786
[6]
A STATIC COMPENSATOR MODEL FOR USE WITH ELECTROMAGNETIC TRANSIENTS SIMULATION PROGRAMS [J].
GOLE, AM ;
SOOD, VK .
IEEE TRANSACTIONS ON POWER DELIVERY, 1990, 5 (03) :1398-1407
[7]
ANALYSIS OF 2ND HARMONIC INSTABILITY FOR THE CHATEAUGUAY HVDC/SVC SCHEME [J].
HAMMAD, AE .
IEEE TRANSACTIONS ON POWER DELIVERY, 1992, 7 (01) :410-415
[8]
VALIDATION OF DIGITAL-SIMULATION OF DC LINKS .2. [J].
INO, T ;
MATHUR, RM ;
IRAVANI, MR ;
SASAKI, S .
IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1985, 104 (09) :2596-2603
[9]
VARIABLE ORDER AND VARIABLE STEP-SIZE INTEGRATION METHOD FOR TRANSIENT ANALYSIS PROGRAMS [J].
KATO, T ;
IKEUCHI, K .
IEEE TRANSACTIONS ON POWER SYSTEMS, 1991, 6 (01) :206-213
[10]
MODELING OF THE DC CONVERTER EQUIPMENT IN THE CARRIER BAND [J].
LAFOREST, JJ ;
LINDH, CB ;
LASSETER, RH ;
REEVE, J .
IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1982, 101 (07) :2137-2145