In vivo measurements show tensile axial strain in the proximal lateral aspect of the human femur

被引:98
作者
Aamodt, A [1 ]
Lund-Larsen, J [1 ]
Eine, J [1 ]
Andersen, E [1 ]
Benum, P [1 ]
Husby, OS [1 ]
机构
[1] Univ Trondheim Hosp, Dept Orthoped Surg, Biomech Lab, N-7006 Trondheim, Norway
关键词
D O I
10.1002/jor.1100150620
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Two conflicting theories exist concerning the stress pattern for the proximal lateral aspect of the human femur. According to the classic theory of Pauwels, a bending moment on the femur leads to compression medially and to tension laterally. The alternative theory is that muscle forces contribute to a moment-free loading of the femur, with both the medial and lateral cortices subjected to compression. To examine these theories, we measured the strain at the external surface of the proximal lateral aspect of the femur of two female patients undergoing surgery for "snapping hip syndrome." During the surgical procedure, a strain-gauge rosette was bonded to the lateral aspect of the femur and the cortical strains were monitored while the patient performed a series of activities. In both patients, principle tensile strain increased significantly during one-legged stance, walking, and stair climbing as compared with that during two-legged stance. During each loading situation, the principal tensile strain was aligned within 22 degrees to the longitudinal femoral axis. Dynamic strain measurements consistently revealed tensile axial strain at the lateral aspect of the femur during each activity. The present study supports the classic bending theory of Pauwels and demonstrates that the proximal lateral aspect of the femur is subjected to tension during the stance phase of gait.
引用
收藏
页码:927 / 931
页数:5
相关论文
共 19 条
[1]
AAMODT A, 1996, ACT ORTHOP SCAN S270, V67, P16
[2]
TELEMETRIC FORCE MEASUREMENTS ACROSS THE HIP AFTER TOTAL ARTHROPLASTY [J].
DAVY, DT ;
KOTZAR, GM ;
BROWN, RH ;
HEIPLE, KG ;
GOLDBERG, VM ;
HEIPLE, KG ;
BERILLA, J ;
BURSTEIN, AH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1988, 70A (01) :45-50
[3]
DUDA GN, 1997, T EUR ORTHOP RES SOC, V7, P167
[4]
FETTO JF, 1994, ORTHOPEDICS, V17, P347
[5]
AN EVALUATION OF 3 LOADING CONFIGURATIONS FOR THE INVITRO TESTING OF FEMORAL STRAINS IN TOTAL HIP-ARTHROPLASTY [J].
FINLAY, JB ;
CHESS, DG ;
HARDIE, WR ;
RORABECK, CH ;
BOURNE, RB .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1991, 9 (05) :749-759
[6]
FROHLING M, 1994, 7 ANN INT S CUST MAD, P40
[7]
GOODSHIP AE, 1992, STRAIN MEASUREMENT B, P70
[8]
Hoffmann K., 1989, INTRO MEASUREMENTS U
[9]
The laws of bone architecture [J].
Koch, JC .
AMERICAN JOURNAL OF ANATOMY, 1917, 21 (02) :177-298
[10]
IS THE PAUWELS THEORY OF HIP BIOMECHANICS STILL VALID - A CRITICAL ANALYSIS, BASED ON MODERN METHODS [J].
KUMMER, B .
ANNALS OF ANATOMY-ANATOMISCHER ANZEIGER, 1993, 175 (03) :203-210