Observation in laparoscopic surgery: Overview of impeding effects and supporting aids

被引:38
作者
Breedveld, P
Stassen, HG
Meijer, DW
Jakimowicz, JJ
机构
[1] Delft Univ Technol, Fac Design Engn & Prod, Dept Mech Engn, Man Machine Syst & Control Grp, NL-2628 CD Delft, Netherlands
[2] Acad Med Ctr, Dept Expt Surg, Amsterdam, Netherlands
[3] Catharina Hosp, Dept Surg, Eindhoven, Netherlands
来源
JOURNAL OF LAPAROENDOSCOPIC & ADVANCED SURGICAL TECHNIQUES-PART A | 2000年 / 10卷 / 05期
关键词
D O I
10.1089/lap.2000.10.231
中图分类号
R61 [外科手术学];
学科分类号
摘要
Within a Dutch research program on minimally invasive surgery, a large literature survey has been carried out. This article describes the state of the art in research on observation in laparoscopy. It gives an overview of factors impeding the surgeon and technical developments designed to overcome these problems. A large number of journals, proceedings, patents, and books starting from the year 1991 have been consulted. The survey was completed with a thorough MEDLINE search. The survey showed that many authors have an incomplete background in the fundamentals of visual perception. This leads to a lack of understanding and to the design of supporting aids that often are not very useful. The new aspect of this study is that it gives a complete and structured overview of laparoscopic observation problems and current solutions. The observation problems are structured according to visual perception theory. The solutions are critically considered, and their benefits and drawbacks are identified. The study shows that the benefits of stereo-endoscopes and motorized endoscope positioners are questionable. The addition of shadows and movement parallax is still a very important research topic.
引用
收藏
页码:231 / 241
页数:11
相关论文
共 81 条
  • [31] Gibson JJ., 1979, The ecological approach to visual perception
  • [32] GREEN PS, 1995, IEEE ENG MED BIO MAY, P324
  • [33] GREGUSS P, 1997, P 8 IEEE INT C ADV R, P833
  • [34] GRIFFIN WP, 1995, BIOMED INSTRUM T MAY, P183
  • [35] GUMB L, 1996, Patent No. 28107
  • [36] Randomised study of influence of two-dimensional versus three-dimensional imaging on performance of laparoscopic cholecystectomy
    Hanna, GB
    Shimi, SM
    Cuschieri, A
    [J]. LANCET, 1998, 351 (9098) : 248 - 251
  • [37] HILL J, 1994, P IEEE C ROB AUT SAN, V3, P2302
  • [38] Under-table mounting for AESOP robot for laparoscopic flank surgery
    Hoenig, DM
    Shalhav, AL
    Arcangeli, CG
    Ostrander, DD
    Elbahnasy, AM
    Clayman, RV
    [J]. MINIMALLY INVASIVE THERAPY & ALLIED TECHNOLOGIES, 1997, 6 (5-6) : 460 - 462
  • [39] Hunter Ian W., 1993, PRESENCE, V2, P265
  • [40] Determination of the learning curve of the AESOP robot
    Jacobs, LK
    Shayani, V
    Sackier, JM
    [J]. SURGICAL ENDOSCOPY-ULTRASOUND AND INTERVENTIONAL TECHNIQUES, 1997, 11 (01): : 54 - 55