Protonation in electrospray mass spectrometry: Wrong-way-round or right-way-round?

被引:127
作者
Zhou, SL [1 ]
Cook, KD [1 ]
机构
[1] Univ Tennessee, Dept Chem, Knoxville, TN 37996 USA
关键词
D O I
10.1016/S1044-0305(00)00174-4
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The term "wrong-way-round ionization" has been used in studies of electrospray ionization to describe the observation of protonated or deprotonated ions when sampling strongly basic or acidic solutions (respectively) where such ions are not expected to exist in appreciable concentrations in solution. Study of the dependence of ionization of the weak base caffeine on the electrospray capillary potential reveals three distinct contributors to wrong-way-round ionization. At near-neutral pH in solutions of low ionic strength, protonation of caffeine results from the surface enrichment of electrolytically produced protons in the surface layer of the droplets from which ions are desorbed. For solutions made strongly basic with ammonia, gas-phase proton transfer from ammonium ions can create protonated caffeine. These two mechanisms have been discussed previously elsewhere. For solutions of high ionic strength at neutral or high pH, the data suggest that discharge-induced ionization is responsible for the production of protonated caffeine. This mechanism probably accounts for some of the wrong-way-round ionization reported elsewhere. (C) 2000 American Society for Mass Spectrometry.
引用
收藏
页码:961 / 966
页数:6
相关论文
共 33 条
[11]  
Hiraoka K, 1995, J Mass Spectrom Soc Jpn, V43, P127, DOI DOI 10.5702/MASSSPEC.43.127
[12]   NEW PICOGRAM DETECTION SYSTEM BASED ON A MASS-SPECTROMETER WITH AN EXTERNAL IONIZATION SOURCE AT ATMOSPHERIC-PRESSURE [J].
HORNING, EC ;
HORNING, MG ;
CARROLL, DI ;
DZIDIC, I ;
STILLWELL, RN .
ANALYTICAL CHEMISTRY, 1973, 45 (06) :936-943
[13]   On the evaporation of small ions from charged droplets [J].
IRIBARNE, JV ;
THOMSON, BA .
JOURNAL OF CHEMICAL PHYSICS, 1976, 64 (06) :2287-2294
[14]  
Kebarle P, 1997, ELECTROSPRAY IONIZAT, P1
[15]   ELECTROSPRAY ANALYSIS OF PROTEINS - A COMPARISON OF POSITIVE-ION AND NEGATIVE-ION MASS-SPECTRA AT HIGH AND LOW PH [J].
KELLY, MA ;
VESTLING, MM ;
FENSELAU, CC ;
SMITH, PB .
ORGANIC MASS SPECTROMETRY, 1992, 27 (10) :1143-1147
[16]  
Konermann L, 1997, BIOCHEMISTRY-US, V36, P12296, DOI 10.1021/bi971266u
[17]   ELECTROSPRAY MASS-SPECTROMETRY OF SOME PROTEINS AND THE AQUEOUS-SOLUTION ACID-BASE-EQUILIBRIUM MODEL IN THE NEGATIVE-ION DETECTION MODE [J].
LEBLANC, JCY ;
GUEVREMONT, R ;
SIU, KWM .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1993, 125 (2-3) :145-153
[18]   ELECTROSPRAY MASS-SPECTRA OF PROTEIN CATIONS FORMED IN BASIC SOLUTIONS [J].
LEBLANC, JCY ;
WANG, JY ;
GUEVREMONT, R ;
SIU, KWM .
ORGANIC MASS SPECTROMETRY, 1994, 29 (11) :587-593
[19]  
Lias S.G, 1988, J PHYS CHEM REF DA S, P17
[20]  
LIDE DR, 1990, CRC HDB CHEM PHYSICS