Magnetic resonance imaging histomorphologic correlation studies on paramagnetic metalloporphyrins in rat models of necrosis

被引:57
作者
Ni, YC [1 ]
Petre, C [1 ]
Miao, Y [1 ]
Yu, J [1 ]
Cresens, E [1 ]
Adriaens, P [1 ]
Bosmans, H [1 ]
Semmler, W [1 ]
Baert, AL [1 ]
Marchal, G [1 ]
机构
[1] INST DIAGNOST FORSCH,BERLIN,GERMANY
关键词
porphyrin; gadolinium; manganese; magnetic resonance imaging contrast media; necrosis; rats;
D O I
10.1097/00004424-199712000-00008
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
RATIONALE AND OBJECTIVES. The authors intended to confirm previous findings that paramagnetic porphyrins are avid only for intratumoral nonviable tissues, but not for viable tumor cells, and to test the hypothesis that necrosis, regardless of location and origin, can be visualized by metalloporphyrin enhanced magnetic resonance imaging (MRT), METHODS. Intravenous administrations of gadolinium mesoporphyrin (Gd-MP), manganese tetraphenylporphyrin (Mn-TPP), manganese methylpyrroporphyrin-gadopentetate dimeglumine complex (Mn-MPP-Gd) and manganese tetra(4-sulfonatophenyl)porphyrin (MnTPPS4) at 0.05 mmol/kg were compared with those of gadopentetate dimeglumine (Gd-DTPA) at 0.1 mmol/kg in 38 rats with cholestatic liver necrosis, alcohol-and laser-induced coagulation necrosis in liver, and skeletal muscle, reperfused hepatic infarction, and segmental renal infarction, T1-weighted spin echo MRI (TR/TE = 300/15 mseconds) was acquired before and as long as 48 hours after injection, matched with histologic findings, and correlated with Gd/Mn tissue content measurements, RESULTS. Both Gd-DTPA and the four metalloporphyrins initially caused a similar nonspecific negative contrast enhancement in the necrosis, However, a strong and persisting positive enhancement (necrosis-to-normal contrast ratio ranging from 1.5 to 2.0) developed only with metalloporphyrins in all types of necrosis, In liver and kidney, Gd and Mn concentrations at 24 hours were comparable in necrotic and normal tissues, In muscle, the concentrations were more than eight times higher in necrotic than in normal tissue. CONCLUSIONS. The implied affinity of metalloporphyrins for necrosis with presumably increased relaxivity suggests a possible mode of targetability for MRI contrast media that may elicit novel applications.
引用
收藏
页码:770 / 779
页数:10
相关论文
共 29 条
[21]   LOCALIZATION OF METALLOPORPHYRIN-INDUCED SPECIFIC ENHANCEMENT IN EXPERIMENTAL LIVER-TUMORS - COMPARISON OF MAGNETIC-RESONANCE-IMAGING, MICROANGIOGRAPHIC, AND HISTOLOGIC-FINDINGS [J].
NI, YC ;
MARCHAL, G ;
YU, J ;
LUKITO, G ;
PETRE, C ;
WEVERS, M ;
BAERT, AL ;
EBERT, W ;
HILGER, CS ;
MAIER, FK ;
SEMMLER, W .
ACADEMIC RADIOLOGY, 1995, 2 (08) :687-699
[22]   METALLOPORPHYRIN CONTRAST ENHANCEMENT OF TUMORS IN MAGNETIC-RESONANCE-IMAGING - A STUDY OF HUMAN CARCINOMA, LYMPHOMA, AND FIBROSARCOMA IN MICE [J].
OGAN, MD ;
REVEL, D ;
BRASCH, RC .
INVESTIGATIVE RADIOLOGY, 1987, 22 (10) :822-828
[23]   PHOTODYNAMIC THERAPY IN ONCOLOGY - MECHANISMS AND CLINICAL USE [J].
PASS, HI .
JNCI-JOURNAL OF THE NATIONAL CANCER INSTITUTE, 1993, 85 (06) :443-456
[24]   MRI CONTRAST-DOSE RELATIONSHIP OF MANGANESE(III)TETRA(4-SULFONATOPHENYL) PORPHYRIN WITH HUMAN XENOGRAFT TUMORS IN NUDE-MICE AT 2.0-T [J].
PLACE, DA ;
FAUSTINO, PJ ;
BERGHMANS, KK ;
VANZIJL, PCM ;
CHESNICK, AS ;
COHEN, JS .
MAGNETIC RESONANCE IMAGING, 1992, 10 (06) :919-928
[25]   MnPcS(4): A new MRI contrast enhancing agent for tumor localisation in mice [J].
Saini, SK ;
Jena, A ;
Dey, J ;
Sharma, AK ;
Singh, R .
MAGNETIC RESONANCE IMAGING, 1995, 13 (07) :985-990
[26]  
SCHNEIDER PD, 1992, SURG CLIN N AM, V72, P623
[27]  
van Zijl P C, 1990, Acta Radiol Suppl, V374, P75
[28]  
WINKELMAN J, 1967, CANCER RES, V27, P2060
[29]   PRECLINICAL EVALUATION OF GADOLINIUM(III) TEXAPHYRIN COMPLEX - A NEW PARAMAGNETIC CONTRAST AGENT FOR MAGNETIC-RESONANCE-IMAGING [J].
YOUNG, SW ;
SIDHU, MK ;
QING, F ;
MULLER, HH ;
NEUDER, M ;
ZANASSI, G ;
MODY, TD ;
HEMMI, G ;
DOW, W ;
MUTCH, JD ;
SESSLER, JL ;
MILLER, RA .
INVESTIGATIVE RADIOLOGY, 1994, 29 (03) :330-338