Optimization methods in chromatography and capillary electrophoresis

被引:154
作者
Siouffi, AM [1 ]
Phan-Tan-Luu, R [1 ]
机构
[1] Univ Aix Marseille 3, Fac Sci St Jerome, F-13397 Marseille 20, France
关键词
reviews; optimization; chemometrics; mathematical modelling;
D O I
10.1016/S0021-9673(00)00247-8
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Many methods have been developed in order to optimize the parameters of interest in either chromatography or capillary electrophoresis, In chemometric approaches experimental measurements are performed in such a way that all factors vary together, An objective function is utilized in which the analyst introduces the desired criteria (selectivity, resolution, time of analysis). Simplex methods and overlapping resolution maps are declining. Factorial designs and central composite designs are more and more popular in electrodriven capillary separations since the number of parameters to master is much larger than in either GC or LC. The use of artificial neural networks is increasing, The advantage of chemometrics tools is that no explicit models are required, conversely the number of experiments to perform may be high and boundaries of the domain are not straightforward to draw and the approach does more than is required. When models are available optimization is easier to perform by regression methods. Computer assisted methods in RPLC are readily available and work well but are still in infancy in CE. Linear solvation energy relationships seem a very valuable tool but estimates of coefficients still require many experiments. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:75 / 106
页数:32
相关论文
共 148 条
[11]   SIMULTANEOUS-OPTIMIZATION OF PH AND ORGANIC MODIFIER CONTENT OF THE MOBILE PHASE FOR THE SEPARATION OF CHLOROPHENOLS USING A DOEHLERT DESIGN [J].
BOURGUIGNON, B ;
MARCENAC, F ;
KELLER, HR ;
DEAGUIAR, PF ;
MASSART, DL .
JOURNAL OF CHROMATOGRAPHY, 1993, 628 (02) :171-189
[12]   STANDARDIZATION OF TEST CONDITIONS FOR HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY COLUMNS [J].
BRISTOW, PA ;
KNOX, JH .
CHROMATOGRAPHIA, 1977, 10 (06) :279-289
[13]   Prediction of the migration behavior of analytes in capillary electrophoresis based on three fundamental parameters [J].
BritzMcKibbin, P ;
Chen, DDY .
JOURNAL OF CHROMATOGRAPHY A, 1997, 781 (1-2) :23-34
[14]  
BROWN R, 1998, ADV CHROMATOGRAPHY, V35
[15]  
Bruzzoniti MC, 1996, J CHROMATOGR A, V728, P55
[16]   Optimization of resolution in micellar electrokinetic chromatography via computer-aided variation of concentrations of sodium dodecyl sulfate and acetonitrile as modifier [J].
Butehorn, U ;
Pyell, U .
JOURNAL OF CHROMATOGRAPHY A, 1997, 772 (1-2) :27-38
[17]   Optimisation of chromatographic separations by use of a chromatographic response function, empirical modelling and multivariate analysis [J].
Bylund, D ;
Bergens, A ;
Jacobsson, SP .
CHROMATOGRAPHIA, 1997, 44 (1-2) :74-80
[18]  
Cela R, 1999, QUIM ANAL, V18, P29
[19]   PREOPT-W: A simulation program for off-line optimization of binary gradient separations in HPLC .1. Fundamentals and overview [J].
Cela, R ;
Lores, M .
COMPUTERS & CHEMISTRY, 1996, 20 (02) :175-191
[20]   COMPUTATIONAL STRATEGY FOR SOLVENT STRENGTH OPTIMIZATION IN REVERSED-PHASE LIQUID-CHROMATOGRAPHY [J].
CHAMINADE, P ;
BAILLET, A ;
FERRIER, D .
JOURNAL OF CHROMATOGRAPHY A, 1994, 672 (1-2) :67-85