Design and fabrication of an integrated cell processor for single embryo cell manipulation

被引:39
作者
Park, J
Jung, SH
Kim, YH
Kim, B
Lee, SK
Park, JO
机构
[1] Korea Inst Sci & Technol, Microsyst Res Ctr, Seoul 130650, South Korea
[2] Dankook Univ, Sch Elect Elect & Comp Engn, Seoul 140714, South Korea
关键词
D O I
10.1039/b404990j
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This paper presents an integrated cell processor for the automatic handling of individual embryo cells. The integrated processor can perform various functions such as cell transport, isolation, orientation, and immobilization. These functions are indispensable and frequently used for the manipulation of single cells, but can only be carried out by a skillful operator. The purpose of this study was the integration and automation of these functions for effective cell manipulation, using a MEMS approach. The isolation of a cell was performed using polypyrrole (PPy) valves in a microchannel into which cells were transported. The orientation of cells was controlled by electrorotation (ER), and the target cell was immobilized by suction from a microhole. All of these functions were seamlessly realized on a single chip. Excellent experimental results with mouse (B6CBA) embryo cells showed that this device could substitute for routine and cumbersome manual work. It is expected that the integrated chip will contribute significantly to faster and more reliable manipulation of cells.
引用
收藏
页码:91 / 96
页数:6
相关论文
共 24 条
[1]   ELECTRO-ROTATION - DEVELOPMENT OF A TECHNIQUE FOR DIELECTRIC MEASUREMENTS ON INDIVIDUAL CELLS AND PARTICLES [J].
ARNOLD, WM ;
ZIMMERMANN, U .
JOURNAL OF ELECTROSTATICS, 1988, 21 (2-3) :151-191
[2]   ELECTROROTATION OF MOUSE OOCYTES - SINGLE-CELL MEASUREMENTS OF ZONE-INTACT AND ZONE-FREE CELLS AND OF THE ISOLATED ZONA-PELLUCIDA [J].
ARNOLD, WM ;
SCHMUTZLER, RK ;
SCHMUTZLER, AG ;
VANDERVEN, H ;
ALHASANI, S ;
KREBS, D ;
ZIMMERMANN, U .
BIOCHIMICA ET BIOPHYSICA ACTA, 1987, 905 (02) :454-464
[3]   Activation and Sorting of Human White Blood Cells [J].
Carlson, Robert H. ;
Gabel, Chris ;
Chan, Shirley ;
Austin, Robert H. .
BIOMEDICAL MICRODEVICES, 1998, 1 (01) :39-47
[4]   Handling individual mammalian embryos using microfluidics [J].
Glasgow, IK ;
Zeringue, HC ;
Beebe, DJ ;
Choi, SJ ;
Lyman, JT ;
Chan, NG ;
Wheeler, MB .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2001, 48 (05) :570-578
[5]  
GUNDEL J, 1989, STUD BIOPHYS, V133, P5
[6]  
Hodgson CE, 1998, CLIN CHEM, V44, P2049
[7]   The cell clinic:: Closable microvials for single cell studies [J].
Jager, EWH ;
Immerstrand, C ;
Peterson, KH ;
Magnusson, KE ;
Lundström, I ;
Inganäs, O .
BIOMEDICAL MICRODEVICES, 2002, 4 (03) :177-187
[8]  
KAUR SA, 1995, INDIAN J PURE AP PHY, V33, P350
[9]  
KIM B, 2003, 2003 IEEE RSJ INT C
[10]  
LEWIS W, 2002, PRINCIPLES DEV