Reporting data from high-throughput screening of small-molecule libraries

被引:77
作者
Inglese, James
Shamu, Caroline E.
Guy, R. Kiplin
机构
[1] US Natl Inst Hlth, Chem Genom Ctr, Natl Human Genome Inst, Bethesda, MD 20892 USA
[2] Harvard Univ, Sch Med, ICCB, Longwood Screening Facil, Boston, MA 02115 USA
[3] St Jude Childrens Hosp, Dept Chem Biol & Therapeut, Memphis, TN 38105 USA
关键词
STATISTICAL PARAMETER; ASSAYS;
D O I
10.1038/nchembio0807-438
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Publications reporting results of small-molecule screens are becoming more common as academic researchers increasingly make use of high-throughput screening (HTS) facilities. However, no standards have been formally established for reporting small-molecule screening data, and often key information important for the evaluation and interpretation of results is omitted in published HTS protocols. Here, we propose concise guidelines for reporting small-molecule HTS data.
引用
收藏
页码:438 / 441
页数:4
相关论文
共 7 条
  • [1] Multiplex analysis of inflammatory signaling pathways using a high-content imaging system
    Bertelsen, Malene
    [J]. MEASURING BIOLOGICAL RESPONSES WITH AUTOMATED MICROSCOPY, 2006, 414 : 348 - 363
  • [2] Standards for systems biology
    Brazma, Alvis
    Krestyaninova, Maria
    Sarkans, Ugis
    [J]. NATURE REVIEWS GENETICS, 2006, 7 (08) : 593 - 605
  • [3] A cell-based assay for IκBα stabilization using a two-color dual luciferase-based sensor
    Davis, R. Eric
    Zhang, Ya-Qin
    Southall, Noel
    Staudt, Louis M.
    Austin, Christopher P.
    Inglese, James
    Auld, Douglas S.
    [J]. ASSAY AND DRUG DEVELOPMENT TECHNOLOGIES, 2007, 5 (01) : 85 - 103
  • [4] The minimum significant ratio: A statistical parameter to characterize the reproducibility of potency estimates from concentration-response assays and estimation by replicate-experiment studies
    Eastwood, BJ
    Farmen, MW
    Iversen, PW
    Craft, TJ
    Smallwood, JK
    Garbison, KE
    Delapp, NW
    Smith, GF
    [J]. JOURNAL OF BIOMOLECULAR SCREENING, 2006, 11 (03) : 253 - 261
  • [5] Statistical and graphical methods for quality control determination of high-throughput screening data
    Gunter, B
    Brideau, C
    Pikounis, B
    Liaw, A
    [J]. JOURNAL OF BIOMOLECULAR SCREENING, 2003, 8 (06) : 624 - 633
  • [6] Orchard Sandra, 2006, Proteomics, V6, P4439, DOI 10.1002/pmic.200600452
  • [7] A simple statistical parameter for use in evaluation and validation of high throughput screening assays
    Zhang, JH
    Chung, TDY
    Oldenburg, KR
    [J]. JOURNAL OF BIOMOLECULAR SCREENING, 1999, 4 (02) : 67 - 73