An improved radioimmunoassay for measurement of pepsinogen in porcine blood samples

被引:19
作者
Banga-Mboko, H [1 ]
Sulon, J
Closset, J
Remy, B
Youssao, I
De Sousa, NM
El Amiri, B
Sangild, PT
Maes, D
Beckers, JF
机构
[1] Univ Liege, Fac Vet Med, Dept Reprod Physiol, Bd Colonster 20 B41, B-4000 Sart Tilman Par Liege, Belgium
[2] Univ Liege, Fac Med, Dept Gen Human Biochem & Pathol, B-4000 Liege, Belgium
[3] Univ Liege, Fac Vet Med, Dept Biostat & Biocomp Sci, B-4000 Sart Tilman Par Liege, Belgium
[4] Univ Marien NGouabi BP 69, Brazzaville, Rep Congo
[5] Royal Vet & Agr Univ, Dept Anim Sci & Hlth, Div Nutr, Frederiksberg, Denmark
[6] Univ Ghent, Fac Vet Med, Dept Reprod Obstet & Herd Hlth, B-9820 Merelbeke, Belgium
关键词
radioimmunoassay; specificity; pepsinogen; ontogeny; pig;
D O I
10.1016/S1090-0233(02)00183-1
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
The study was conducted to develop a sensitive and specific radioimmunoassay (RIA) for the measurement of pepsinogen in porcine serum, and to use this test for the determination of pepsinogen concentrations in serum samples from fetuses and pigs of different ages. Compared to a previously described RIA, major improvements were made concerning the use of specific polyclonal antibodies and the use of an appropriate buffer. The assay was able to detect pepsinogen concentrations of greater than or equal to 0.2 ng/mL. The recovery of pepsinogen was close to 95%. The intra-assay coefficients of variations ranged between 3.9 and 7.5% whereas the interassay ranged between 8.8 and 11.9%. These percentages correspond to a satisfactory accuracy and reproducibility of the assay. No cross-reactions were observed with the main commercially available products of the aspartic proteases family except porcine pepsin cross-reacted over 62.5 mug/mL. Pepsinogen concentrations increased steadily with increasing age of the fetuses and the pigs (P < 0.05). Pepsinogen concentrations (+/-SE) in fetuses of 90-100 (n = 24) and 100-110 days of pregnancy (n = 36) were 0.5 +/- 0.1 and 5.3 +/- 1.3 ng/mL, respectively. In pigs of 21, 98, and 213 days of age, the pepsinogen concentrations were 290.6 +/- 10.8, 343.1 +/- 17.9 and 383.5 +/- 15.3 ng/mL, respectively. The results demonstrate that RIA is accurate and can be used easily to assess pepsinogen concentrations in pig sera. The test may constitute a valuable tool in epidemiological surveys and in studies related to gastric diseases in pigs. (C) 2003 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:288 / 295
页数:8
相关论文
共 35 条
  • [1] BANGAMBOKO H, 2001, 2 BELG WORKSH AN END, P25
  • [2] BIEMOND I, 1989, J CLIN CHEM CLIN BIO, V27, P19
  • [3] OBSERVATIONS ON PLASMA GASTRIN AND PLASMA PEPSINOGEN IN RELATION TO WEANING AND GASTRIC (PARS-OESOPHAGEA) ULCERATION IN PIGS
    BUNN, CM
    HANSKY, J
    KELLY, A
    TITCHEN, DA
    [J]. RESEARCH IN VETERINARY SCIENCE, 1981, 30 (03) : 376 - 378
  • [4] CHARD T, 1995, INTRO RADIOIMMUNOASS, P185
  • [5] CHIANG CS, 1987, CLIN CHEM, V33, P1245
  • [6] Eysker M, 2000, PARASITOLOGY, V120, pS109, DOI 10.1017/S0031182099005752
  • [7] FOLTMANN B, 1987, P NUTR SOC, V46, pA26
  • [8] FRANCHIMONT P, 1970, ANN BIOL CLIN-PARIS, V28, P3
  • [9] GJESDAL E, 1972, ACTA VET SCAND, V40, P1
  • [10] A NEW METHOD FOR BOVINE PEPSINOGEN PURIFICATION - PREPARATION OF A SPECIFIC ANTIBODY
    GOMES, MA
    LIMA, WD
    PESQUERO, JL
    [J]. JOURNAL OF IMMUNOASSAY, 1994, 15 (02): : 157 - 170