摘要
Among computational models, voxel phantoms based on computer tomographic (CT), nuclear magnetic resonance (NMR) or colour photographic images of patients, volunteers or cadavers have become popular in recent years. Although being true to nature representations of scanned individuals, voxel phantoms have limitations, especially when walled organs have to be segmented or when volumes of organs or body tissues, like adipose, have to be changed. Additionally, the scanning of patients or volunteers is usually made in supine position, which causes a shift of internal organs towards the ribcage, a compression of the lungs and a reduction of the sagittal diameter especially in the abdominal region compared to the regular anatomy of a person in the upright position, which in turn can influence organ and tissue absorbed or equivalent dose estimates. This study applies tools developed recently in the areas of computer graphics and animated films to the creation and modelling of 3D human organs, tissues, skeletons and bodies based on polygon mesh surfaces. Female and male adult human phantoms, called FASH (Female Adult meSH) and MASH (Male Adult meSH), have been designed using software, such as MakeHuman, Blender, Binvox and ImageJ, based on anatomical atlases, observing at the same time organ masses recommended by the International Commission on Radiological Protection for the male and female reference adult in report no 89. 113 organs, bones and tissues have been modelled in the FASH and the MASH phantoms representing locations for adults in standing posture. Most organ and tissue masses of the voxelized versions agree with corresponding data from ICRP89 within a margin of 2.6%. Comparison with the mesh-based male RPI_AM and female RPI_AF phantoms shows differences with respect to the material used, to the software and concepts applied, and to the anatomies created.
引用
收藏
页码:133 / 162
页数:30
相关论文
共 85 条
[41]   Hybrid computational phantoms of the 15-year male and female adolescent: Applications to CT organ dosimetry for patients of variable morphometry [J].
Lee, Choonsik ;
Lodwick, Daniel ;
Williams, Jonathan L. ;
Bolch, Wesley E. .
MEDICAL PHYSICS, 2008, 35 (06) :2366-2382
[42]   NURBS-based 3-d anthropomorphic computational phantoms for radiation dosimetry applications [J].
Lee, Choonsik ;
Lee, Choonik ;
Lodwick, Daniel ;
Bolch, Wesley E. .
RADIATION PROTECTION DOSIMETRY, 2007, 127 (1-4) :227-232
[43]   Hybrid computational phantoms of the male and female newborn patient: NURBS-based whole-body models [J].
Lee, Choonsik ;
Lodwick, Daniel ;
Hasenauer, Deanna ;
Williams, Jonathan L. ;
Lee, Choonik ;
Bolch, Wesley E. .
PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (12) :3309-3333
[44]  
MIN P, 2009, BINVOX 3D MESH VOXEL
[45]   A Mesh-Based Anatomical Deformation Method for Creating Size-Adjustable Whole-Body Patient Models [J].
Na, Y. ;
Zhang, J. ;
Xu, X. .
MEDICAL PHYSICS, 2008, 35 (06) :2665-+
[46]   Development of realistic high-resolution whole-body voxel models of Japanese adult males and females of average height and weight, and application of models to radio-frequency electromagnetic-field dosimetry [J].
Nagaoka, T ;
Watanabe, S ;
Sakurai, K ;
Kunieda, E ;
Watanabe, S ;
Taki, M ;
Yamanaka, Y .
PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (01) :1-+
[47]  
*NAT I HLTH, 2009, IMAGEJ IM PROC AN JA
[48]  
NIPPER JC, 2002, PHYS MED BIOL, V44, P2213
[49]   Simplification and repair of polygonal models using volumetric techniques [J].
Nooruddin, FS ;
Turk, G .
IEEE TRANSACTIONS ON VISUALIZATION AND COMPUTER GRAPHICS, 2003, 9 (02) :191-205
[50]   The GSF family of voxel phantoms [J].
Petoussi-Henss, N ;
Zankl, M ;
Fill, U ;
Regulla, D .
PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (01) :89-106