Endoluminal repair of infrarenal abdominal aortic aneurysms with use of stent-grafts - A new interventional technique

被引:22
作者
Blum, U
Langer, M
Spillner, G
Beyersdorf, F
BuitragoTellez, C
Voshage, G
Weinbeck, M
Schlosser, V
Ehmer, M
Cragg, A
机构
[1] UNIV FREIBURG, RADIOL KLIN, RONTGENDIAGNOST ABT, W-7800 FREIBURG, GERMANY
[2] UNIV FREIBURG, CHIRURG KLIN, ABT HERZ & GEFASSCHIRURG, W-7800 FREIBURG, GERMANY
[3] UNIV FREIBURG, ABT RADIOL, FREIBURG, GERMANY
[4] UNIV FREIBURG, ANASTHESIOL KLIN, FREIBURG, GERMANY
[5] FAIRVIEW RIVERSIDE MED CTR, MINNEAPOLIS, MN USA
来源
FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN | 1996年 / 164卷 / 01期
关键词
abdominal aortic aneurysm; stent-graft; endoluminal treatment;
D O I
10.1055/s-2007-1015607
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: With a series of 31 transluminal stent-graft procedures, we assessed the feasibility and clinical effectiveness of a new stent-graft for the treatment of infrarenal abdominal aortic aneurysms (AAAs). Methods: We treated the patients (male; mean age 71 years) with straight or bifurcated nitinol stents covered with woven dacron graft material for infrarenal eccentric saccular AAA (n = 4) or AAA involving the bifurcation and the common iliac arteries (n = 27). The 18-F delivery system was advanced via a surgical arteriotomy and the stent-graft, was placed under fluoroscopic control. Follow-up period ranged from 8 days to 9 months. Results: The implantation of the stent-grafts was technically successful in 30/31 cases. Procedure-related complications were acute hepatic failure due to gastric bleeding in a patient with liver cirrhosis, graft occlusion due to emboli originating hom the left atrium (n = 1), macro-embolisation (n = 3), local haematoma (n = 1) and av-fistula (n = 1) requiring surgery. A post-implantation syndrome with leukocytosis and elevated C-reactive, protein was observed in all patients. Conclusions: Endoluminal repair of infrarenal AAA with use of dacron covered nitinol stent-grafts is feasible, safe and clinically effective. However, careful long-term evaluation is necessary.
引用
收藏
页码:47 / 54
页数:8
相关论文
共 27 条
[1]   TRANS-FEMORAL PLACEMENT OF INTRALUMINAL POLYURETHANE PROSTHESIS FOR ABDOMINAL AORTIC-ANEURYSM [J].
BALKO, A ;
PIASECKI, GJ ;
SHAH, DM ;
CARNEY, WI ;
HOPKINS, RW ;
JACKSON, BT .
JOURNAL OF SURGICAL RESEARCH, 1986, 40 (04) :305-309
[2]  
BROUDGHENE F, 1993, JVIR, V4, P497
[3]  
BROWN OW, 1981, ARCH SURG-CHICAGO, V116, P1484
[4]   TRANSFEMORAL ENDOVASCULAR AORTIC GRAFT PLACEMENT [J].
CHUTER, TAM ;
GREEN, RM ;
OURIEL, K ;
FIORE, WM ;
DEWEESE, JA ;
QUERAL, LA ;
CRIADO ;
NATH, RL ;
BERKOWITZ, HD ;
SUMPIO, BE .
JOURNAL OF VASCULAR SURGERY, 1993, 18 (02) :185-197
[5]  
COLLIN J, 1988, LANCET, V2, P613
[6]   NITINOL INTRAVASCULAR STENT - RESULTS OF PRECLINICAL EVALUATION [J].
CRAGG, AH ;
DEJONG, SC ;
BARNHART, WH ;
LANDAS, SK ;
SMITH, TP .
RADIOLOGY, 1993, 189 (03) :775-778
[7]   ENDO-ANEURYSMORRHAPHY AND TREATMENT OF AORTIC ANEURYSM [J].
CREECH, O .
ANNALS OF SURGERY, 1966, 164 (06) :935-+
[8]   TRANSLUMINALLY-PLACED COILSPRING ENDARTERIAL TUBE GRAFTS - LONG-TERM PATENCY IN CANINE POPLITEAL ARTERY [J].
DOTTER, CT .
INVESTIGATIVE RADIOLOGY, 1969, 4 (05) :329-+
[9]   RESECTION OF AN ANEURYSM OF THE ABDOMINAL AORTA - REESTABLISHMENT OF THE CONTINUITY BY A PRESERVED HUMAN ARTERIAL GRAFT, WITH RESULT AFTER 5 MONTHS [J].
DUBOST, C ;
ALLARY, M ;
OECONOMOS, N .
AMA ARCHIVES OF SURGERY, 1952, 64 (03) :405-408
[10]  
ERNST CB, 1993, NEW ENGL J MED, V328, P1167